Related Experiment Video
Updated: Jan 19, 2026

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Prediction of Milk Coagulation Properties and Individual Cheese Yield in Sheep Using Partial Least Squares Regression
Massimo Cellesi1, Fabio Correddu2, Maria Grazia Manca3
1Dipartimento di Agraria, Sezione di Scienze Zootecniche, Università degli Studi di Sassari, Viale Italia 39, 07100 Sassari, Italy. mcellesi@uniss.it.
Abstract:
The objectives of this study were (i) the prediction of sheep milk coagulation properties (MCP) and individual laboratory cheese yield (ILCY) from mid-infrared (MIR) spectra by using partial least squares (PLS) regression, and (ii) the comparison of different data pre-treatments on prediction accuracy. Individual milk samples of 970 Sarda breed ewes were analyzed for rennet coagulation time (RCT), curd-firming time (k20), and curd firmness (a30) using the Formagraph instrument; ILCY was measured by micro-manufacturing assays. An Furier-transform Infrared (FTIR) milk-analyzer was used for the estimation of the milk gross composition and the recording of MIR spectrum. The dataset (n = 859, after the exclusion of 111 noncoagulating samples) was divided into two sub-datasets: the data of 700 ewes were used to estimate prediction model parameters, and the data of 159 ewes were used to validate the model. Four prediction scenarios were compared in the validation, differing for the use of whole or reduced MIR spectrum and the use of raw or corrected data (locally weighted scatterplot smoothing). PLS prediction statistics were moderate. The use of the reduced MIR spectrum yielded the best results for the considered traits, whereas the data correction improved the prediction ability only when the whole MIR spectrum was used. In conclusion, PLS achieves good accuracy of prediction, in particular for ILCY and RCT, and it may enable increasing the number of traits to be included in breeding programs for dairy sheep without additional costs and logistics.
Related Concept Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Regression Toward the Mean
04:16Individualized Reconstitution of Human Milk Microbiota: A Feasible Approach in Real-World Settings
Punnett Squares
06:14Estimating the Yield of Compounds on the TLC Plate via the Blue-LED Illumination Technique
