Selecting Arthroplasty Fixation Approach Based on Greater Trochanter Fracture Type in Unstable Intertrochanteric

Min-Wook Kim1, Young-Yool Chung1, Sung-An Lim1

  • 1Department of Orthopaedic Surgery, Kwangju Christian Hospital, Gwangju, Korea.

Hip & Pelvis
|September 11, 2019
PubMed
Abstract

Related Concept Videos

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner04:41

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner

Here, we present a protocol for accessing the guidewire of intramedullary femoral nailing in obese patients using an in-house designed awl. Using the new awl with a distal positioner for the guidewire insertion and opening the bone can increase efficiency in inserting the guidewire and reduce the difficulty of...
930
Establishing a Diaphyseal Femur Fracture Model in Mice05:46

Establishing a Diaphyseal Femur Fracture Model in Mice

This protocol describes a surgical procedure for the establishment of a diaphyseal fracture in the femur of mice, which is stabilized with an intramedullary wire, for fracture healing...
3.0K
Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling15:11

Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling

Here we present a method to stabilize sternal fractures by using locked titanium plates in a low profile design. Performing subperiosteal dissection along the sternum while reducing the fracture, using depth limited drilling, and fixing the plates provides a safe surgical...
65.0K
Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents06:59

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents

The goal of the protocol is to optimize the fracture generation parameters to yield consistent fractures. This protocol accounts for the variations in bone size and morphology that may exist between animals. Additionally, a cost-effective, adjustable fracture apparatus is...
14.1K
Three-Dimensional Reconstruction of Orbital Fractures08:18

Three-Dimensional Reconstruction of Orbital Fractures

Personalized medicine for orbital reconstruction is developing rapidly. Due to the delicate nature of the orbit, small discrepancies following fracture reconstruction may cause impairment in visual perception. Here, we describe three methods for virtual 3D reconstruction of orbital defects and their indications and potential pitfalls for correct reconstruction.
636
Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models04:13

Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models

This protocol presents a comprehensive and efficient method for analyzing mandibular bone repair. We describe a reproducible technique for non-stabilized mandibular fracture in a mouse model, allowing analysis of the process of endochondral bone repair with minimal tissue damage and bone loss.
848