General methods for the characterization of the nonuniformity of a radiometric calibration source
Abstract:
The spatial nonuniformity of a radiometric calibration source is key to its performance, uncertainty budget, and utility. Multiple disparate approaches are currently used to assess nonuniformity; thus, it is critical to understand how nonuniformity is calculated when comparing radiometric calibration sources. Two factors are key in assessing nonuniformity: (1) the methodology chosen to calculate the nonuniformity and (2) how the intensity of the light is sampled. Here, we present and compare different methodologies of calculating spatial nonuniformity. In general, we find that these methods can be categorized into two groups: those in which the equations assume a Gaussian population distribution and those in which the equations can be applied to any shape of distribution. Additionally, we compare different methods of sampling the light intensity within the region of interest. We show that peak deviation nonuniformity analysis, in which the pixels of the image of the illumination source are resampled into 69 equally sized bins encompassing the region of interest, can be used to effectively assess the nonuniformity of any radiance distribution. Furthermore, the nonuniformity determined by this method allows for an accurate comparison to industry standard nonuniformity metrics.
More Related Videos
Related Concept Videos
Radioactive Decay and Radiometric Dating
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves
Calibration curves are used to understand the instrumental response to an analyte and predict the concentration in an unknown sample. Generally, a set of standard samples are made at various concentrations with a range than includes the unknown of interest and the instrumental response at each concentration is recorded. For more accuracy and to understand the error, the response at each concentration can be repeated so an error...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following: