Related Concept Videos

Clot Retraction and Fibrinolysis01:16

Clot Retraction and Fibrinolysis

After a fibrin clot is formed, the next step is clot retraction, a vital process facilitated by platelet contractile proteins, such as actin and myosin. These proteins pull the fibrin strands closer together and condense the clot. This action reduces the size of the clot, creating a smaller, denser structure that effectively seals off the damaged vessel. Clot retraction consolidates the clot and helps with wound healing by bringing the edges of the damaged blood vessel closer together.
8.5K
In Situ Measurement of Vacuum Window Birefringence using 25Mg+ Fluorescence07:03

In Situ Measurement of Vacuum Window Birefringence using 25Mg+ Fluorescence

Presented here is a method to measure the birefringence of vacuum windows by maximizing the fluorescence counts emitted by Doppler cooled 25Mg+ ions in an ion trap. The birefringence of vacuum windows will change the polarization states of the laser, which can be compensated by changing the azimuthal angles of external wave...
4.2K
Fabrication Procedures and Birefringence Measurements for Designing Magnetically Responsive Lanthanide Ion Chelating Phospholipid Assemblies09:38

Fabrication Procedures and Birefringence Measurements for Designing Magnetically Responsive Lanthanide Ion Chelating Phospholipid Assemblies

Fabrication procedures for highly magnetically responsive lanthanide ion chelating polymolecular assemblies are presented. The magnetic response is dictated by the assembly size, which is tailored by extrusion through nanopore membranes. The assemblies' magnetic alignability and temperature-induced structural changes are monitored by birefringence measurements, a complimentary technique to nuclear magnetic resonance and small angle neutron...
7.5K
Ultrasonic Assessment of Myocardial Microstructure10:53

Ultrasonic Assessment of Myocardial Microstructure

Echocardiography is commonly used to noninvasively characterize and quantify changes in cardiac structure and function. We describe an ultrasound-based imaging algorithm that offers an enhanced surrogate measure of myocardial microstructure and can be performed using open-access image analysis...
5.8K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
517
Layer Microdissection of Tricuspid Valve Leaflets for Biaxial Mechanical Characterization and Microstructural Quantification07:34

Layer Microdissection of Tricuspid Valve Leaflets for Biaxial Mechanical Characterization and Microstructural Quantification

This protocol describes the biaxial mechanical characterization, polarized spatial frequency domain imaging-based collagen quantification, and microdissection of tricuspid valve leaflets. The provided method elucidates how the leaflet layers contribute to the holistic leaflet...
2.4K