An Orthogonal Approach for Determination of Acetamide Content in Pharmaceutical Drug Substance and Base-Contaminated

Nagaraju Rajana1,2, Kaviaraj M Yarbagi1, K Balakumaran1

  • 1Technology Development centre, Custom Pharmaceutical Services, Dr. Reddys Laboratories Ltd., Miyapur, Hyderabad 500 049, India.

Related Concept Videos

Gas Chromatography (GC) with Flame-Ionization Detection09:22

Gas Chromatography (GC) with Flame-Ionization Detection

Source: Laboratory of Dr. B. Jill Venton - University of Virginia
Gas chromatography (GC) is used to separate and detect small molecular weight compounds in the gas phase. The sample is either a gas or a liquid that is vaporized in the injection port. Typically, the compounds analyzed are less than 1,000 Da, because it is difficult to vaporize larger compounds. GC is popular for environmental monitoring and industrial applications because it is very reliable and can be run nearly continuously....
291.3K
Isolation of Mandibular Gland Reservoir Contents from Bornean 'Exploding Ants' (Formicidae) for Volatilome Analysis by GC-MS and MetaboliteDetector11:07

Isolation of Mandibular Gland Reservoir Contents from Bornean 'Exploding Ants' (Formicidae) for Volatilome Analysis by GC-MS and MetaboliteDetector

Minor workers of the ant species Colobopsis explodens are dissected to isolate the wax-like content stored in their hypertrophied mandibular gland reservoirs for subsequent solvent-extraction and analysis by gas chromatography-mass spectrometry. The annotation and identification of volatile constituents using the open-source software MetaboliteDetector is also...
9.2K
Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS11:59

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS

This protocol presents a fully automated workflow for the extraction of geosmin and 2-methylisoborneol from water and lipid-rich fish tissues. The method allows for the early detection of these molecules before they reach odor thresholds. Representative data from an aquaculture setting are...
1.4K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.6K
Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry (GC-MS)-based Metabolomics07:21

Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry (GC-MS)-based Metabolomics

This protocol describes how to prepare Drosophila larvae for GC-MS-based metabolomic...
11.6K
Mutagenesis and Analysis of Genetic Mutations in the GC-rich KISS1 Receptor Sequence Identified in Humans with Reproductive Disorders12:49

Mutagenesis and Analysis of Genetic Mutations in the GC-rich KISS1 Receptor Sequence Identified in Humans with Reproductive Disorders

Mutations in the kisspeptin receptor (KISS1R) are associated with reproductive disorders in patients. Here we describe how to introduce mutations of interest in the GC-rich sequence of KISS1R as well as the use of KISS1R constructs to characterize the degradation pathway of the receptor by immunoprecipitation and western...
14.4K