Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Evaluation of UVA emission from x-ray megavoltage-irradiated tissues and phantoms
Sagarika Jain1,2, Suk W Yoon1, Xiaofeng Zhang3
1Duke University Medical Physics Graduate Program, Durham, NC, United States of America.
Abstract:
RECA (Radiotherapy enhanced with Cherenkov photo-activation) is a proposed treatment where the anti-cancer drug psoralen is photo-activated in situ by UVA (Ultraviolet A, 320-400 nm) Cherenkov light (CL) produced directly by the treatment beam itself. In this study, we develop a UVA-imaging technique to quantify relative UVA CL produced by bulk tissues and other phantoms upon clinical x-ray megavoltage irradiation. UVA CL emission (320-400 nm) was quantified in tissue samples of porcine and poultry and in two kinds of solid waters (SW): brown (Virtual Waters, Standard Imaging, WI) and white (Diagnostic Therapy, CIRS, VA), and in 1% agarose gels variously doped with absorbing dye. Quantification was achieved through cumulative imaging of the samples placed in a dark, light-blocking chamber during irradiation on a Varian 21 EX accelerator. UVA imaging required a specialized high-sensitivity cooled camera equipped with UVA lenses and a filter. At 15 MV, white SW emitted [Formula: see text], [Formula: see text] and [Formula: see text] less UVA than chicken breast, pork loin and pork belly, respectively. Similar under-response was observed at 6 MV. Brown SW had [Formula: see text] less UVA emission than white SW at 15 MV, and negligible emission at 6 MV. Agarose samples (1% by weight) doped with 250 ppm India ink exhibited equivalent UVA CL emission to chicken breast (within 8%). The results confirm that for the same absorbed dose, SW emits less UVA light than the tissue samples, indicating that prior in vitro studies utilizing SW as the CL-generating source may have underestimated the RECA therapeutic effect. Agarose doped with 250 ppm India ink is a convenient tissue-equivalent phantom for further work.
Related Concept Videos
06:51Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
02:17Measuring TEER in X-ray-Irradiated Epithelial Cells Co-cultured With PBMCs
10:22Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure
11:40A Co-culture Method to Investigate the Crosstalk Between X-ray Irradiated Caco-2 Cells and PBMC
05:11Multimodal 3D Printing of Phantoms to Simulate Biological Tissue
09:25Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy