SAVR versus TAVI: What about the Hemodynamic Performance? An In Vivo and In Vitro Analysis

Kaveh Eghbalzadeh1, Parwis Baradaran Rahmanian1, Daniel Giese2

  • 1Department of Cardiothoracic Surgery, Uniklinik Koln, Koln, Germany.

Abstract

Related Concept Videos

Drug Product Performance: In Vitro–In Vivo Correlation01:20

Drug Product Performance: In Vitro–In Vivo Correlation

In pharmaceutical development, it's crucial to establish a predictive in vitro–in vivo correlation (IVIVC) for two or more formulations to gain a comprehensive understanding of release properties. IVIVC reduces the need for costly in vivo studies and facilitates the establishment of meaningful dissolution specifications with significant cost savings and decreased regulatory burden. Furthermore, a meaningful IVIVC should predict Cmax and AUC within 20%, aligning with FDA guidance while...
239
Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom06:26

Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom

The present protocol describes particle image velocimetry (PIV) measurements performed to investigate the sinus flow through the in vitro setup of the transcatheter aortic valve (TAV). The hemodynamic parameters based on velocity are also...
4.8K
Optimized Analysis of In Vivo and In Vitro Hepatic Steatosis08:58

Optimized Analysis of In Vivo and In Vitro Hepatic Steatosis

Here, optimized methods to generate in vivo and in vitro models of hepatic steatosis and to analyze the steatotic phenotypes and related physiological parameters are described.
16.8K
Systems Analysis of the Neuroinflammatory and Hemodynamic Response to Traumatic Brain Injury07:21

Systems Analysis of the Neuroinflammatory and Hemodynamic Response to Traumatic Brain Injury

This protocol presents methods to characterize the neuroinflammatory and hemodynamic response to mild traumatic brain injury and to integrate these data as part of a multivariate systems analysis using partial least squares...
3.6K
Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS08:12

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS

We present a protocol of creating right ventricular dysfunction in a pig model by inducing ARDS. We demonstrate invasive monitoring of left and right ventricular cardiac output using flow probes around the aorta and the pulmonary artery, as well as blood pressure measurements in the aorta and pulmonary...
10.5K
Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents05:44

Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents

This article details how to perform in vivo (using surface and needle electrode arrays) and ex vivo (using a dielectric cell) electrical impedance myography on the rodent gastrocnemius muscle. It will demonstrate the technique in both mice and rats and detail the modifications available, (i.e., obese animals,...
3.5K