Comparison of torque, force generation and canal shaping ability between manual and nickel-titanium glide path
Pyae Hein Htun1, Arata Ebihara2, Keiichiro Maki1
1Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan.
Abstract:
This study aimed to analyze force/torque generation and canal volume changes of NiTi rotary glide path preparation using HyFlex EDM Glide Path File in comparison to manual stainless steel K-file instrumentation. Thirty extracted mandibular incisors with a minimally curved and narrow root canal were randomly divided into three groups (n = 10) according to the instrumentation kinematics: Optimum Glide Path motion (OGP) or continuous rotation (CR) with HyFlex EDM Glide Path Files using a custom-made automated-root-canal-preparation device and manual instrumentation with stainless steel K-files (SS) in watch-winding motion. Torque and force were monitored with a custom-made torque/force analyzing device. Canal volume changes and transportation values were measured on micro-computed tomographic images taken before and after the glide path preparation. The data were statistically evaluated using Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction, with a significance level set at 5%. Maximum upward apical force, representing the screw-in force, was lower in groups OGP and CR compared with that in group SS (P < 0.05). Group CR showed the highest maximum clockwise torque value and canal volume changes, followed by groups OGP and SS (P < 0.05). Canal transportation values at 1 and 3 mm from the apex were not significantly different among groups. Within the limitations of this study, rotary glide path preparation generated smaller screw-in force, larger torque and larger canal volume changes than manual preparation. OGP motion generated smaller torque and less canal volume changes than CR.
Related Concept Videos
Gliding Motility in Phormidium lacuna Filaments
07:55Flexural Rigidity Measurements of Biopolymers Using Gliding Assays
Mean free path and Mean free time
Path Between Thermodynamics States
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...