Related Experiment Video
Updated: Jan 19, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Safety of catheter ablation for atrial fibrillation in the octogenarian population
Jorge Romero1, Gbolahan Ogunbayo2, Samy C Elayi2
1Montefiore Medical Center, Albert Einstein College of Medicine, New York.
Introduction:
Catheter ablation (CA) has been shown to be an effective treatment for atrial fibrillation (AF). The complication rates and outcomes among octogenarians remain poorly studied. We aimed to compare trends, morbidity, and mortality associated with CA for AF among octogenarians versus those less than 80 years old.
Methods:
Using weighted sampling from the National Inpatient Sample database, we identified patients with a primary diagnosis of AF and a primary procedure of CA (2004-2013). Our primary outcome was mortality. Secondary outcomes included incidence of major and minor complications.
Results:
Among 86,119 patients who underwent CA for AF, 3,482 were 80 years old or older. Complications were significantly more frequent in octogenarians; [16.2% (564 of 3,482) versus 9.8% (8,092 of 82,637), P < 0.001]. Of note, there was no significant difference for the composite of major complications; [3.6% (124 of 3482) in octogenarians versus 2.8% (2286 of 82637), P = 0.20]. The total mortality rate was not significant in a multivariate regression analysis (odds ratio [OR], 0.96; 95% confidence interval [CI], 0.35-2.64; P = .94). The presence of chronic renal failure (OR, 4.19; 95% CI, 2.75-6.36; P < 0.001), anemia (OR, 1.75; 95% CI, 1.03-2.97; P = .04), and chronic pulmonary disease (OR, 1.75; 95% CI, 1.11-2.62; P = .015) were predictors of major complications in octogenarians.
Conclusion:
Catheter ablation for AF in octogenarians does not confer a higher mortality risk than in those less than 80 years old. The procedure is associated with a higher rate of overall complications but there was no difference in terms of major complications or death. The presence of anemia, CKD or pulmonary disease were predictors of major complications in octogenarians.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
Related Concept Videos
11:21Robotic Ablation of Atrial Fibrillation
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
05:43Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
05:12Transesophageal Atrial Burst Pacing for Atrial Fibrillation Induction in Rats
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation