Objectives:
To differentiate electrograms representing sites of active atrial fibrillation (AF) drivers from passive ones.
Background:
Ablation of complex-fractionated atrial electrograms (CFAEs) is controversial due to difficulty in distinguishing CFAEs representing sites of active AF drivers from passive mechanisms. We hypothesized that active CFAE sites exhibit repetitive wavefront directionality, thereby inscribing an electrogram conformation (Egm-C) that is more recurrent compared with passive CFAE sites; and that can be differentiated from passive CFAEs using nonlinear recurrence quantification analysis (RQA).
Methods:
We developed multiple computer models of active CFAE mechanisms (ie, rotors) and passive CFAE mechanisms (ie, wavebreak, slow conduction, and double potentials). CFAE signals were converted into discrete time-series representing Egm-C. The RQA algorithm was used to compare signals derived from active CFAE sites to those from passive CFAEs sites. The RQA algorithm was then applied to human CFAE signals collected during AF ablation (n = 17 patients).
Results:
RQA was performed in silico on simulated bipolar CFAEs within active (n = 45) and passive (n = 60) areas. Recurrence of Egm-C was significantly higher in active compared with passive CFAE sites (31.8% ± 19.6% vs 0.3% ± 0.5%, respectively, P < .0001) despite no difference in mean cycle length (CL). Similarly, for human AF (n = 39 signals), Egm-C recurrence was higher in active vs passive CFAE areas despite similar CLs (%recurrence 13.6% ± 15.5% vs 0.1% ± 0.3%, P < .002; mean CL 102.5 ± 14.3 vs 106.6 ± 14.4, P = NS).
Conclusion:
Active CFAEs critical to AF maintenance exhibit higher Egm-C recurrence and can be differentiated from passive bystander CFAE sites using RQA.
Related Concept Videos
11:21Robotic Ablation of Atrial Fibrillation
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
05:12Transesophageal Atrial Burst Pacing for Atrial Fibrillation Induction in Rats
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation