Objective:
Ultrasonography remains the initial imaging modality in the management of biliary disease. This study is designed to evaluate the accuracy of transabdominal ultrasonography in diagnosing biliary pathology in patients with choledocholithiasis.
Methods:
This was a retrospective study of a continuous sample of patients over a period of 3 years ending in January 2016; these patients were referred for endoscopic management of choledocholithiasis to a tertiary care hospital in Colombo, Sri Lanka. Ultrasound reporting was carried out by different consultant radiologists at both the index and the referring hospitals. The findings of endoscopic retrograde cholangiograms were compared with the ultrasound scan (USS) results.
Results:
A total of 247 patients were included in the study. USS was 97.4% accurate in detecting intrahepatic duct dilatation (IHDD). Stone counts and the location of stone(s) in the USSs correlated strongly with the number of stones delivered during endoscopic removal and their location in cholangiograms (P < 0.001). The difference in mean diameter of the common bile duct (CBD) of patients with choledochal cysts (CCs) (18.57 mm) and of patients without them (12.39 mm) is statistically significant (P < 0.001). At 14.5 mm, the negative predictive value for a CC is 99.02%.
Conclusion:
Ultrasonography is a reliable tool in predicting IHDD, stone count, and the location of stones in the biliary tree, particularly in a resource-poor setting. A CBD diameter of 14.5 mm in transabdominal ultrasound scan can be used as a cutoff for predicting extrahepatic CC.
Related Concept Videos
19:57An Affordable HIV-1 Drug Resistance Monitoring Method for Resource Limited Settings
07:40Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Choosing Between Projects: Limited Resources
For example, a chocolate manufacturing company has a $100,000 budget and two projects under consideration. Project A requires an investment of $80,000, with...
07:46Setting Limits on Supersymmetry Using Simplified Models
06:05Employing Transcranial Magnetic Stimulation in a Resource Limited Environment to Establish Brain-Behavior Relationships
09:36Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings