Related Experiment Video
Updated: Jan 19, 2026

Wind Tunnel Experiments to Study Chaparral Crown Fires
Published on: November 14, 2017
Extremely Large Non-equilibrium Tunnel Magnetoresistance Ratio in CoRhMnGe Based Magnetic Tunnel Junction by
Yu Feng1, Zhenxiang Cheng2, Xiaotian Wang3
1Laboratory for Quantum Design of Functional Materials, School of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou, China.
Abstract:
Equiatomic quaternary Heusler compounds (EQHCs) generally have the advantages of high Curie temperature, large spin polarization and long spin diffusion length, and they are regarded as one of the most promising candidates for spintronics devices. Herein, we report a theoretical investigation on an EQHC CoRhMnGe based magnetic tunnel junction (MTJ) with (i) MnGe-terminated interface and (ii) modified pure Mn terminated interface, i.e., MnMn-terminated interface. By employing first principle calculations combined with non-equilibrium Green's function, the local density of states (LDOS), transmission coefficient, spin-polarized current, tunnel magnetoresistance (TMR) ratio and spin injection efficiency (SIE) as a function of bias voltage are studied. It reveals that when the MTJ under equilibrium state, TMR ratio of MnGe-terminated structure is as high as 3,438%. When the MTJ is modified to MnMn-terminated interface, TMR ratio at equilibrium is enhanced to 2 × 105%, and spin filtering effects are also strengthened. When bias voltage is applied to the MTJ, the TMR ratio of the MnGe-terminated structure suffers a dramatic loss. While the modified MnMn-terminated structure could preserve a large TMR value of 1 × 105%, even bias voltage rises up to 0.1 V, showing a robust bias endurance. These excellent spin transport properties make the CoRhMnGe a promising candidate material for spintronics devices.
Related Concept Videos
09:27Wind Tunnel Experiments to Study Chaparral Crown Fires
12:45Detection and Quantification of Tunneling Nanotubes Using 3D Volume View Images
Turbulence Sphere Method: Evaluating Wind Tunnel Flow Quality
Wind tunnel tests are useful in the design of vehicles and structures that are subjected to airflow during their use. Wind tunnel data are generated by applying a controlled air flow to a model of the object being studied. The test model usually has a similar geometry but is a smaller scale compared to the full-sized object. To ensure accurate and useful data is collected...
05:25A Wind Tunnel for Odor Mediated Insect Behavioural Assays
04:08Metacarpal Small Incision for Carpal Tunnel Syndrome
09:04A Burrowing/Tunneling Assay for Detection of Hypoxia in Drosophila melanogaster Larvae

