A Novel Dual-Phase Activation-Dependent Foot-Switch Mechanism for Surgical Energy Devices as an Asset in Early
Abdalla Eisawi1, Myat Aung2, Ruben Canelo2,3
1Torbay Hospital, Torquay, UK.
Abstract:
Introduction. Many processes exist that limit or eliminate the incidence of adverse events in general surgery including the World Health Organization safety checklist. Technology and device advancement has a potentially expanding role in the context of surgical safety. Materials and Methods. A dual controlled accessory electrical diathermy footswitch (Permissive diathermy foot switch device or PDf) device concept was developed in an effort to improve patient safety in theatre and enhance opportunities in training. Electrical diathermy is only activated if the senior supervising surgeon and the novice surgeon simultaneously activate their interconnected footswitches. The activation of the PDf accessory footswitch device allows a senior surgeon to exert control on "initiation" of activation of diathermy devices operated by a novice surgeon (foot on pedal) as well as when desiring to deactivate the device (foot off pedal). Results. A process of designing and prototyping was initiated to define the purpose and the functionality of the PDf device up till the stage of a fully functioning prototype. The PDf device was constructed as a final working and tested prototype in association with the local medical engineering department at the Cumberland Infirmary in Carlisle. The device was on a nonbiological model to determine efficacy and safety and passed its laboratory testing phase and was deemed ready for clinical use. Conclusion. We demonstrated the feasibility and functionality of the PDf device and propose a positive role in surgical training in the context of early surgical training and specific circumstances where more control is needed.
More Related Videos
08:11Surgical Training for the Implantation of Neocortical Microelectrode Arrays Using a Formaldehyde-fixed Human Cadaver Model
Published on: November 19, 2017
08:55Use of a Foot-Induced Digitally Controlled Resistance Device for Functional Magnetic Resonance Imaging Evaluation in Patients with Foot Paresis
Published on: July 7, 2023
Related Concept Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
08:11Surgical Training for the Implantation of Neocortical Microelectrode Arrays Using a Formaldehyde-fixed Human Cadaver Model
08:55Use of a Foot-Induced Digitally Controlled Resistance Device for Functional Magnetic Resonance Imaging Evaluation in Patients with Foot Paresis
04:03Surgical Labyrinthectomy of the Rat to Study the Vestibular System
09:51Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators
05:24Surgical Lumbar Sympathectomy in Mice
