Related Experiment Video
Updated: Jan 19, 2026
Operation of High-Performance Liquid Chromatography HPLC
Published on: April 30, 2023
Comprehensive stability-indicating high-performance liquid chromatography coupled with diode array detection method
Mostafa M Baker1, Dina S El-Kafrawy2, Magdi M Abdel-Khalek2
1Methodology Department, Pharco Pharmaceuticals Company, Alexandria, Egypt.
Abstract:
This research deals with the development of a stability-indicating high-performance liquid chromatography method for simultaneous determination of amprolium hydrochloride and ethopabate. To the best of our knowledge, no comprehensive stability-indicating method has been reported for analysis of this mixture. Separation was achieved using Kromasil cyano column with gradient elution of the mobile phase composed of sodium hexane sulfonate solution and methanol. Quantification was based on measuring peak areas at 266 nm. Amprolium and ethopabate peaks eluted at retention times 10.42 and 18.53 min, respectively. The proposed procedure was validated with respect to system suitability, linearity, ranges, precision, accuracy, specificity, robustness, detection, and quantification limits. Linearity ranges for amprolium and ethopabate were 1.5-240 and 1-160 μg/mL, respectively. Analytes were subjected to stress conditions of hydrolysis, oxidation and thermal degradation. The proposed method enabled resolution of drugs from their forced-degradation products and amprolium related substance (2-picoline). Moreover, specificity was verified by resolution of the analytes from about 22 drugs used in antimicrobial veterinary products. The validated method was successfully applied to assay of the combined veterinary powder dosage form, additionally it was implemented in the accelerated stability study of the dosage form when stored for six months at 40°C and 75% relative humidity.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography (HPLC)
High-performance liquid chromatography (HPLC) is an important analytical method commonly used to separate and quantify components of liquid samples. In this technique, a solution (first phase) is pumped through a column that contains a packing of small porous particles with a second phase bound to the surface. The different solubilities of the sample components in the two phases cause the components to move through the column with different average...
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
11:01Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
High-Performance Liquid Chromatography: Elution Process