Detection method for the complex amplitude of a signal beam with intensity and phase modulation using the transport

Related Concept Videos

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

We show how to encode the complex field of laser beams by using a single phase element. A common-path interferometer is employed to mix the phase information displayed into a phase-only spatial light modulator to finally retrieve the desired complex field pattern at the output of an optical imaging...
10.3K
Quasi-light Storage for Optical Data Packets07:45

Quasi-light Storage for Optical Data Packets

The article describes a procedure to store optical data packets with an arbitrary modulation, wavelength, and data rate. These packets are the basis of modern...
11.3K
Demonstration of Equal-Intensity Beam Generation by Dielectric Metasurfaces09:33

Demonstration of Equal-Intensity Beam Generation by Dielectric Metasurfaces

A protocol for the fabrication and optical characterization of dielectric metasurfaces is presented. This method can be applied to the fabrication of not only beam splitters, but also of general dielectric metasurfaces, such as lenses, holograms, and optical...
6.6K
Sound Intensity00:58

Sound Intensity

The loudness of a sound source is related to how energetically the source is vibrating, consequently making the molecules of the propagation medium vibrate. To measure the loudness of a source, the physical quantity of interest is the intensity. This is defined as the energy emitted per unit of time per unit of area perpendicular to the sound wave's propagation direction. Since the total energy is greater if the source vibrates for a longer duration and over a larger area, dividing the...
4.7K
Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System08:08

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System

This study describes a protocol to evaluate the targeting accuracy in the focal plane of an ultrasound-guided high-intensity focused ultrasound phased-array...
5.6K
Method for the Assessment of Effects of a Range of Wavelengths and Intensities of Red/near-infrared Light Therapy on Oxidative Stress In Vitro08:16

Method for the Assessment of Effects of a Range of Wavelengths and Intensities of Red/near-infrared Light Therapy on Oxidative Stress In Vitro

Non-coherent Xenon light was passed through narrow-band interference and neutral density filters to deliver light of varying wavelength and intensity to cultured cells. This protocol was used to assess the effects of red/near-infrared light therapy on production of reactive species in vitro: no effects were observed using the tested...
9.1K