Online distributed strain measurement of fiber Michelson hydrophones based on DPP-BOTDA with a pulsed-probe wave

Optics Express
|September 13, 2019
PubMed

Related Concept Videos

Ultrasound-based Pulse Wave Velocity Evaluation in Mice08:07

Ultrasound-based Pulse Wave Velocity Evaluation in Mice

Arterial stiffness represents a key factor in cardiovascular disease and pulse wave velocity (PWV) can be considered as a surrogate index for arterial stiffness. This protocol describes an image processing algorithm for calculating PWV in mice based on ultrasound image processing that is applicable at different arterial...
14.4K
Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes06:56

Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes

A sampling moiré technique featuring 2-pixel and multi-pixel sampling methods for high-accuracy strain distribution measurements at the micro/nano-scale is presented...
12.7K
Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model09:32

Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model

This manuscript describes a detailed protocol for using high frequency ultrasound imaging to measure luminal diameter, pulse propagation velocity, distensibility and radial strain on a mouse model of abdominal aortic...
6.8K
Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness05:51

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness

This protocol describes a method to standardize the measurements of carotid-femoral pulse wave velocity to evaluate arterial...
18.4K
Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging06:08

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging

Pulse wave velocity (PWV) measurement assesses arterial stiffness by a tonometry-based system that measures the speed with which arterial pressure wave travels along the arterial tree, typically approximating the time that it takes this wave to travel from the descending aorta (using the carotid artery as a surrogate) to the femoral artery. Carotid-femoral PWV increases two- to threefold across the adult...
17.7K
Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

We demonstrate use of a fiber optic distributed sensor for mapping the temperature field of mixing air jets. The Rayleigh scattering-based sensor generates thousands of data points along a single fiber to provide exceptional spatial resolution that is unattainable with traditional sensors such as...
12.4K