Related Experiment Video
Updated: Jan 19, 2026

Simulator Training for Endovascular Neurosurgery
Published on: May 6, 2020
A newly designed 0.018-in.-compatible inner dilator as a novel option for endovascular therapy with the crossover
Noriyuki Wakana1, Kan Zen2, Daisuke Kambayashi3
1Department of Cardiovascular Medicine, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kamigyo-ku, Kyoto, 602-8566, Japan.
Abstract:
This study aimed to investigate the efficacy of guiding sheath delivery with the crossover approach using a newly customized inner dilator for a 0.018-in. guidewire of the Destination® guiding sheath (Terumo Corporation, Tokyo, Japan) (18-system), compared with that of the conventional-type 0.035-in. guidewires with inner dilators (35-system), and to predict failure of guiding sheath delivery. We conducted a prospective multicenter case series study of the contralateral crossover approach using Destination®, to determine whether the 18-system could be a rescue system in cases in which the conventional 35-system failed. To evaluate the efficacy of the 18-system, we created an in vitro aortoiliac bifurcation model by using a silicone vessel. We enrolled 172 cases consecutively. The initial crossover approach with the 35-system failed in 37 cases (21.5%), and a second attempt with the 18-system was successful in all failed cases. The bifurcation angles in the 35-system failure cases were significantly steeper than those in the 35-system success cases. A receiver operating characteristic curve analysis demonstrated that an aortoiliac bifurcation angle of 68° was the optimal cut-off value for predicting failure of the crossover procedure. Data from the analysis using the silicone vessel model suggested that the 18-system provided superior results, especially in aortoiliac bifurcation angles steeper than 60°, consistent with the in vivo findings. The results of the initial use of the 18-system with the crossover approach suggest that it may be superior to the conventional 35-system, especially in cases of steeper aortoiliac bifurcation angles.
More Related Videos
14:58Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
Related Concept Videos
08:08Simulator Training for Endovascular Neurosurgery
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
14:58Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Dosage Regimens: Designs and Approaches
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices