Design and Evaluation of a Gas Chromatograph-Atmospheric Pressure Chemical Ionization Interface for an Exactive
Joshua B Powers1,2, Shawn R Campagna3,4
1Department of Chemistry, University of Tennessee, Knoxville, TN, 37996-1600, USA.
Abstract:
Various separation and mass spectrometric (MS) techniques have furthered our ability to study complex mixtures, and the desire to measure every analyte in a system is of continual interest. For many complex mixtures, such as the total molecular content of a cell, it is becoming apparent that no one single separation technique or analysis is likely to achieve this goal. Therefore, having a variety of tools to measure the complexity of these mixtures is prudent. Orbitrap MSs are broadly used in systems biology studies due to their unique performance characteristics. However, GC-Orbitraps have only recently become available, and instruments that can use gas chromatography (GC) cannot use liquid chromatography (LC) and vice versa. This limits small molecule analyses, such as those that would be employed for metabolomics, lipidomics, or toxicological studies. Thus, a simple, temporary interface was designed for a GC and Thermo Scientific™ Ion Max housing unit. This interface enables either GC or LC separation to be used on the same MS, an Exactive™ Plus Orbitrap, and utilizes an atmospheric pressure chemical ionization (APCI) source. The GC-APCI interface was tested against a commercially available atmospheric pressure photoionization (APPI) interface for three types of analytes that span the breadth of typical GC analyses: fatty acid methyl esters (FAMEs), polyaromatic hydrocarbons (PAHs), and saturated hydrocarbons. The GC-APCI-Orbitrap had similar or improved performance to the APPI and other reported methods in that it had a lower limit of quantitation, better signal to noise, and lower tendency to fragment analytes.
More Related Videos
Related Concept Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
08:19Direct Analysis of Single Cells by Mass Spectrometry at Atmospheric Pressure
09:22Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Gas Chromatography (GC) with Flame-Ionization Detection
Gas chromatography (GC) is used to separate and detect small molecular weight compounds in the gas phase. The sample is either a gas or a liquid that is vaporized in the injection port. Typically, the compounds analyzed are less than 1,000 Da, because it is difficult to vaporize larger compounds. GC is popular for environmental monitoring and industrial applications because it is very reliable and can be run nearly continuously....