Exploiting the aiming beam to increase the safety of laser lithotripsy: Experimental evaluation of light reflection

Birgit Lange1, Jens Cordes2, Ralf Brinkmann1

  • 1Medical Laser Center Lübeck, D-23562, Lübeck, Germany.

Abstract

Related Concept Videos

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

We show how to encode the complex field of laser beams by using a single phase element. A common-path interferometer is employed to mix the phase information displayed into a phase-only spatial light modulator to finally retrieve the desired complex field pattern at the output of an optical imaging...
10.3K
Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses06:55

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

This protocol describes the scanning light scattering profiler (SLSP) that enables the full-angle quantitative evaluation of forward and backward scattering of light from intraocular lenses (IOLs) using goniophotometer...
8.0K
Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology10:41

Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology

The combination of laser poration and microelectrode arrays (MEA) allows action potential-like recordings of cultivated primary and stem cell-derived cardiomyocytes. The waveform shape provides superior insight into test compounds' mode of action than standard recordings. It links patch-clamp and MEA readout to further optimize cardio safety research in the...
2.5K
High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip14:09

High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip

Chip-based super-resolution optical microscopy is a novel approach to fluorescence microscopy and offers advantages in cost effectiveness and throughput. Here, the protocols for chip preparation and imaging are shown for TIRF microscopy and localization-based super-resolution...
7.4K
Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses10:20

Evaluation of Photosynthetic Behaviors by Simultaneous Measurements of Leaf Reflectance and Chlorophyll Fluorescence Analyses

We describe a new technical approach to study photosynthetic responses in higher plants involving simultaneous measurements of chlorophyll a fluorescence and leaf reflectance using a PAM and a spectral radiometer for the detection of signals from the same leaf area in...
13.2K
Cell Imaging Using Total Internal Reflection Fluorescence Microscopy02:51

Cell Imaging Using Total Internal Reflection Fluorescence Microscopy

Source: Daniele, F., et. al TIRFM and pH-sensitive GFP-probes to Evaluate Neurotransmitter Vesicle Dynamics in SH-SY5Y Neuroblastoma Cells: Cell Imaging and Data Analysis. J. Vis. Exp. (2015).This video demonstrates the imaging of human neuroblastoma cells using a total internal reflection fluorescence (TIRF) microscope to visualize fluorophore-tagged synaptic vesicles. The cells are first focused in epifluorescence mode. Adjustments are then made to achieve total internal reflection,...
603