Aim:
To determine high frequency diathermocoagulation operation modes safe for periodontal tissues and providing the best antimicrobial effect in the root canal system. In vitro study was conducted on 12 extracted upper and lower incisors. High frequency monopolar diathermocoagulation device DK-35MS (2640 kHz; 1.5 kΩ) in six operation modes was used. Root surface heating degree was measured with compact infrared radiation converter (thermal imager Seek Thermal) and distance infrared thermometer Testo 830-T1. After determination of safe operation modes antibacterial effect was assessed. The strains of Streptococcus sanguis, Streptococcus mutans, Enterococcus faecalis, Escherichia coli and Candida albicans were obtained from root canals with inflamed pulp.
Results:
for endodontic diathermocoagulation procedure the safe operation modes (for the tissues surrounding the tooth) were #3, #4 and #6 with the capacity 3.06-5.4 W for 3 seconds. In operation modes #3 and #6 with the power 5.4 W and 4.1 W, respectively, the best antimicrobial effect was achieved against the studied microorganisms.
Conclusion:
High frequency monopolar diathermocoagulation can be used in endodontic treatment. The recommended power modes of diathermocoagulation in root canals are 4.1 W and 5.4 W, the recommended time is 3 seconds. These operation modes do not cause root surface heating and provide antimicrobial effect against endodontic pathogens.
Related Concept Videos
07:14Guided Endodontics: Three-Dimensional Planning and Template-Aided Preparation of Endodontic Access Cavities
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
07:03Dynamic Navigation in Endodontics: Guided Access Cavity Preparation by Means of a Miniaturized Navigation System
06:32Operating Procedures of the Electrochemotherapy for Treatment of Tumor in Dogs and Cats
08:48Low-cost Custom Fabrication and Mode-locked Operation of an All-normal-dispersion Femtosecond Fiber Laser for Multiphoton Microscopy
08:14Determining the Optimal Inhibitory Frequency for Cancerous Cells Using Tumor Treating Fields (TTFields)