Related Experiment Video
Updated: Jan 19, 2026

Experimental Methods to Study Human Postural Control
Published on: September 11, 2019
Comparative analysis of postural control and vertical jump performance between three different measurement devices
Christopher Blosch1, Robin Schäfer1, Markus de Marées1
1Department of Sports Medicine and Sports Nutrition, Ruhr-University Bochum, Bochum, Germany.
Objectives:
The aim of this study was to examine the concurrent validity of the HUMAC Balance System (HBS) and Balance Trainer BTG4 (BTG) in comparison to a laboratory-grade force platform (FP) for postural control (PC) and vertical jump performance (VJP) assessment. In addition, reliability of the three devices was measured for PC.
Methods:
Overall 22 participants (age = 37.8 ± 13.3 years; gender = 9 male, 13 female; height = 174.1 ± 10.5 cm; body mass = 75.3 ± 17.6 kg) were recruited to participate. Double and single leg standing balance tests with eyes open or closed and counter movement jumps (CMJ) were performed on two separate occasions. Reliability and concurrent validity for COP parameters and VJP were examined using intraclass correlation coefficients (ICC), Bland-Altman plots (BAP), standard error of measurement (SEM) and minimum detectable change (MDC).
Results:
COP path length test-retest reliability was predominantly good to excellent for all three devices (ICC = 0.80-0.95). SEM and MDC values were high for all plates (SEM% = 8.0-15.2; MDC% = 22.8-44.5), with the HBS MDC values higher than the KIS and BTG in three of the four trials. ICC scores for concurrent validity were good to excellent for the BTG (ICC = 0.76-0.93) and moderate to good for the HBS (0.49-0.83). Band-Altman plots revealed a systematic bias for the HBS towards higher COP path length values under all conditions and for the BTG in two out of four trials towards lower values. Validity of VJP was excellent for the BTG (ICC = 1.0) and poor for the HBS (0.34), with a systematic bias towards lower values.
Conclusion:
The comparative analysis of PC and VJP revealed reliable and valid results for the BTG in comparison to a laboratory-grade force plate. The HBS showed reliable results for PC assessment with restrictions regarding its validity. Results of VJP showed that the HBS revealed deficits in the assessment of activities that require rapid, high force movements such as jumping and running. Due to the variable results of all three devices, it is recommended not to use them interchangeably.
Related Concept Videos
08:12Experimental Methods to Study Human Postural Control
Hydraulic Jumps
When liquid flows along an open channel at high velocity, the flow can become unstable, and slight disturbances can cause the liquid upper surface to transition abruptly to a higher level (Fig. 1a). This sharp increase in the liquid level is called a hydraulic jump. The increase in the liquid level causes a reduction in the average flow velocity....
14:52Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
07:52Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
06:21Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function
10:08Effects of a Novel Neuromuscular Training Intervention on Jump, Sprint, and Change of Direction in Adult Female Soccer Players
