Related Experiment Video
Updated: Jan 19, 2026

Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
Published on: September 25, 2009
The Morphology of Somatosensory Evoked Potentials During Middle Cerebral Artery Aneurysm Clipping (MoSAC): A Pilot
Franca Tecchio1, Federico Cecconi1, Elisabetta Colamartino2
1Laboratory of Electrophysiology for Translational neuroScience (LET'S) and Laboratory of Agent Based Social Simulation (LABSS), ISTC, CNR, Rome, Italy.
Abstract:
Somatosensory evoked potential (SEP) monitoring is a standard tool during clipping of aneurysms of the middle cerebral artery (MCA), and the parameter used to detect a state of cortical ischemia is amplitude. We think that the sensitivity of SEP can however be improved by using other parameters. Our study moves in this direction via SEP morphology. In this pilot preliminary study, involving a small sample without postoperative neurological deficit, we aimed at investigating the value of SEP morphology (in the 15- to 35-ms time frame), in comparison with SEP amplitude (N20 peak-to-peak), as a measure of sensitivity to blood flow reduction. The changes in the SEP morphology of 16 patients undergoing clipping of an unruptured MCA aneurysm was studied. We applied the Morph-Fréchet index for each recorded SEP (at 30-second intervals), quantifying the pattern shape change with regard to the average SEP recorded after dura opening (baseline). We also compared 3 measurements of the SEP morphology, without and with GARCH-derived filter. Filtered Morph-Fréchet never exceeded the individual's "normality" range in baseline but did so in 81% of the risk phase on average across the 16 subjects, which is more than that for amplitude (36%, P = .002). This pilot study indicates that a measurement derived from the networking nature of the brain was sensitive to blood flow reduction. The SEP morphology approach promises to improve SEP monitoring sensitivity during clipping of unruptured MCA aneurysms. New and Noteworthy. The higher sensitivity to blood flow reduction of SEP morphology than amplitude promises to improve the effectiveness of intraoperative monitoring during MCA aneurysm clipping procedures.
Related Concept Videos
18:50Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
05:32Transient Middle Cerebral Artery Occlusion Model of Stroke
06:32Microelectrode Impalement Method to Record Membrane Potential from a Cannulated Middle Cerebral Artery
07:43Utilizing a Cranial Window to Visualize the Middle Cerebral Artery During Endothelin-1 Induced Middle Cerebral Artery Occlusion
04:18A Modified Model Preparation for Middle Cerebral Artery Occlusion Reperfusion
13:50Focal Cerebral Ischemia Model by Endovascular Suture Occlusion of the Middle Cerebral Artery in the Rat

