Background:
Microcalcification clusters in mammograms can be considered as early signs of breast cancer. However, their detection is a very challenging task because of different factors: large variety of breast composition, highly textured breast anatomy, impalpable size of microcalcifications in some cases, as well as inherent low contrast of mammograms. Thus, the need to support the clinicians' work with an automatic tool.
Methods:
In this work a three-phases approach for clustered microcalcification detection is presented. Specifically, it is made up of a pre-processing step, aimed at highlighting potentially interesting breast structures, followed by a single microcalcification detection step, based on Hough transform, that is able to grasp the innate characteristic shape of the structures of interest. Finally, a cluster identification step to group microcalcifications is carried out by means of a clustering algorithm able to codify expert domain rules.
Results:
The detection performance of the proposed method has been evaluated on 364 mammograms of 182 patients obtaining a true positive ratio of 91.78% with 2.87 false positives per image.
Conclusions:
Experimental results demonstrated that the proposed method is able to detect microcalcification clusters in digital mammograms showing performance comparable to different methodologies exploited in the state-of-art approaches, with the advantage that it does not require any training phase and a large set of data. The performance of the proposed approach remains high even for more difficult clinical cases of mammograms of young women having high-density breast tissue thus resulting in a reduced contrast between microcalcifications and surrounding dense tissues.
Related Concept Videos
13:44Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
10:55Digital Microfluidics for Automated Proteomic Processing
08:22Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
07:21Automated, High-Throughput Detection of Bacterial Adherence to Host Cells
13:28Automated Detection and Analysis of Exocytosis