PACS Integration of Semiautomated Imaging Software Improves Day-to-Day MS Disease Activity Detection
A Dahan1, R Pereira2,3, C B Malpas4,5
1From the Department of Radiology (A.D.), Austin Hospital, Heidelberg, Australia ariel.dahan@austin.org.au.
Background And Purpose:
The standard for evaluating interval radiologic activity in MS, side-by-side MR imaging comparison, is restricted by its time-consuming nature and limited sensitivity. VisTarsier, a semiautomated software for comparing volumetric FLAIR sequences, has shown better disease-activity detection than conventional comparison in retrospective studies. Our objective was to determine whether implementing this software in day-to-day practice would show similar efficacy.
Materials And Methods:
VisTarsier created an additional coregistered image series for reporting a color-coded disease-activity change map for every new MS MR imaging brain study that contained volumetric FLAIR sequences. All other MS studies, including those generated during software-maintenance periods, were interpreted with side-by-side comparison only. The number of new lesions reported with software assistance was compared with those observed with traditional assessment in a generalized linear mixed model. Questionnaires were sent to participating radiologists to evaluate the perceived day-to-day impact of the software.
Results:
Nine hundred six study pairs from 538 patients during 2 years were included. The semiautomated software was used in 841 study pairs, while the remaining 65 used conventional comparison only. Twenty percent of software-aided studies reported having new lesions versus 9% with standard comparison only. The use of this software was associated with an odds ratio of 4.15 for detection of new or enlarging lesions (P = .040), and 86.9% of respondents from the survey found that the software saved at least 2-5 minutes per scan report.
Conclusions:
VisTarsier can be implemented in real-world clinical settings with good acceptance and preservation of accuracy demonstrated in a retrospective environment.
Related Concept Videos
08:30One-day Workflow Scheme for Bacterial Pathogen Detection and Antimicrobial Resistance Testing from Blood Cultures
11:16Isolation of Protoplasts from Tissues of 14-day-old Seedlings of Arabidopsis thaliana
14:05Generation of Hook Ischemia-Reperfusion Model using a Three-Day Developing Chick Embryo
10:16Accurate and Phenol Free DNA Sexing of Day 30 Porcine Embryos by PCR
06:10Extrahepatic Bile Duct and Gall Bladder Dissection in Nine-Day-Old Mouse Neonates
06:50Analyzing Neural Activity and Connectivity Using Intracranial EEG Data with SPM Software