Related Experiment Video
Updated: Jan 19, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
The patient results and satisfaction of knee arthroplasty in a validated grading system
Christiaan Rudolf Oosthuizen1,2, Catherine Van Der Straeten3, Innocent Maposa4
1Private Orthopaedic Practice, Johannesburg, South Africa. drcroosthuizen@gmail.com.
Introduction:
The validated Knee Osteoarthritis Grading System (KOGS) was implemented and clinical results were compared with patient satisfaction data and implant survivorship in a multi-centre study with surgeons familiar with unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA) and total knee arthroplasty (TKA). This is also the first study to evaluate the prevalence of UKA and TKA in consecutive osteoarthritis (OA) knee arthroplasties assessed by this system..
Method:
A consecutive cohort of knees was gathered at three different institutions as categorized by KOGS and surgically treated with the recommended implant unless clinical reasons or patient preference precluded such an option. One thousand one hundred seventy-seven consecutive knees were evaluated including 311 TKA (26%), 695 medial UKA (59%), 154 lateral UKA (13%) and 17 PFA (2%) and the results of the categories evaluated with the Oxford Knee Score (OKS) and the complications reflected in the different categories.
Results:
The failure rate of the UKA (3.5%) or TKA (1.6%) is not higher than accepted results in the literature and the difference in complications is negligible between the UKA (72%) and TKA (26%) cohorts. Revision of a UKA to a TKA as an endpoint was 0.58% with ipsilateral progression at 0.8% over a period of five to 84 months (mean follow-up of 36 months) despite the 'excessive' proportion of UKA in this cohort. The Oxford Score improvement is significant in TKA and UKA and contributes to the acceptable outcomes (The OKS for TKA improved from 20 pre-operatively to 36 post-operatively and the UKA improved from 22 pre-operatively to 39 post-operatively).
Conclusion:
KOGS achieves acceptable early survival and functional results when implemented and is a suitable tool for identifying the preferred implant as was validated.
Related Concept Videos
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
10:10Reverse Total Shoulder Arthroplasty
04:41Knee Arthrocentesis in Adults
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
07:19Generation and Culturing of High-Grade Serous Ovarian Cancer Patient-Derived Organoids
Knee Exam
The knee is a hinged joint that connects the femur with the tibia. It is the largest joint in the body, and due to its location in the middle of the lower leg, it is subjected to a variety of traumatic and degenerative forces. Examination of the knee can be quite complex, owing to the fact it is an inherently unstable joint held together by various ligaments and supported by menisci, which act as shock absorbers and...