Time-of-flight mass spectrometers based on a wedge-shaped electrostatic mirror with a two-dimensional field

Igor Spivak-Lavrov1, Orda Baisanov2, Evgeniy Yakushev3

  • 1Aktobe Regional State University named after K. Zhubanov, Aktobe, Kazakhstan.

Abstract

Related Concept Videos

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry08:23

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry

A protocol for characterizing chemical composition of exhaled breath in real time by using secondary nanoelectrospray ionization coupled to high resolution mass spectrometry is...
9.3K
Mass Spectrometers01:16

Mass Spectrometers

This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
8.4K
Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

A two-dimensional gas chromatography-time-of-flight mass spectrometry method is described for characterization of the aqueous fraction of bio-crude produced from hydrothermal liquefaction of algae. This protocol can also be employed to analyze the aqueous fraction of liquid products from fast pyrolysis, catalytic fast pyrolysis, catalytic deoxygenation and hydro-treating.
9.8K
Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators11:44

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators

The robust device design of fringing-field electrostatic MEMS actuators results in inherently low squeeze-film damping conditions and long settling times when performing switching operations using conventional step biasing. Real-time switching time improvement with DC-dynamic waveforms reduces the settling time of fringing-field MEMS actuators when transitioning between up-to-down and down-to-up...
10.7K
Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry07:24

Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry

Time-of-flight secondary ion mass spectrometry is applied to demonstrate the chemical mapping and corrosion morphology at the metal-paint interface of an aluminum alloy after being exposed to a salt solution compared with a specimen exposed to...
8.7K
Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics09:18

Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics

Conformational flexibility plays a critical role in protein function. Herein, we describe the use of time-resolved electrospray ionization mass spectrometry coupled to hydrogen-deuterium exchange for probing the rapid structural changes that drive function in ordered and disordered...
10.3K