Related Experiment Video
Updated: Jan 19, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Safety and Efficacy of MRI Scans in Patients With Implanted Microvascular Coupling Devices
Neelam Phalke1, W Walsh Thomas2, James Azzi2
1Department of Otolaryngology, Louisiana State University School of Medicine, New Orleans, Louisiana.
Objective:
To demonstrate the safety and compatibility of microvascular couplers in patients undergoing postoperative magnetic resonance imaging (MRI) scans.
Study Design:
Retrospective case series.
Methods:
A consecutive review of 1,252 patients undergoing free tissue transfer for head and neck reconstruction at Oregon Health and Sciences University (OHSU) between 2010 and 2017 who had microvascular coupler Synovis, Baxter Deerfield, IL (Synovis Life Technologies, Saint Paul, MN) implantation were reviewed. One hundred fifteen patients had a subsequent MRI scan, which consisted of a variety of Phillips (Amsterdam, Netherlands) MRI machines ranging from 1.0 to 3.0 Tesla (T) in magnetic strength.
Results:
These 115 patients underwent 121 free flaps with 131 couplers (including 32 flow couplers) utilized for venous anastomoses. Couplers ranged in size from 1.5 to 4.0 mm (3.0 mm [42%] followed by 3.5 mm [21%], 2.5 mm [19%], 2.0 mm [10%], 4.0 mm [6%], and 1.5 mm [2%]. Three hundred fifty-nine MRI scans (2 days to 91 months postoperatively) were obtained with 233 MRIs for cancer surveillance, and the remaining were obtained for neurologic disease, injury, or evaluation for metastases. No complications occurred related to the MRI and the metallic components of the coupler or other metal implants, such as reconstruction bars, vascular clips, or metallic surgical mesh. Additionally, no radiology report commented on MRI distortion due to the coupler placement, which contrasts the distortion seen with the other metallic implants.
Conclusion:
Microvascular couplers and their constitutive stainless-steel pins have not been found to cause any complications in a large series of consecutive patients undergoing multiple MRIs with magnetic strength up to 3 T. The U.S. Food and Drug Administration advocates medical alert notification for patients with couplers; however, hesitation regarding potential MRI scanning for surveillance or otherwise is unwarranted.
Level Of Evidence:
4 Laryngoscope, 130:1428-1430, 2020.
More Related Videos
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
10:02Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Related Concept Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
10:02Whole-body PET/MRI of Pediatric Patients: The Details That Matter
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
07:33In Vivo Evaluation of Fracture Callus Development During Bone Healing in Mice Using an MRI-compatible Osteosynthesis Device for the Mouse Femur
In Vivo MRI Analysis of Cranial Nerve Morphology in a Patient with Inner Ear Disorder