Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
Published on: March 14, 2018
Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a
Maikol Salas-Ramirez1, Johannes Tran-Gia1, Uwe Gbureck2
1Department of Nuclear Medicine, University of Würzburg, Würzburg, Germany.
Abstract:
A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification method using dual-energy quantitative computed tomography (DEQCT) for the quantification of trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy. First, a phantomless quantification method (mass fraction method) based on x-ray beam and detector sensitivity was validated in an integrated dual energy SPECT/CT and in a dual source computed tomography (DSCT) system for comparison. The validation was performed in a phantom consisting of different water, fat and hydroxyapatite compositions. Moreover, the European spine phantom (ESP) was used to simulate the spine geometry. Bone mineral content (BMC) of the whole vertebra and bone mineral density (BMD) in the spongiosa region of each phantom vertebra were measured using DEQCT and dual energy x-ray absorptiometry (DEXA). Lastly, BMC was measured in a patient using DEQCT and DEXA. Measured values of hydroxyapatite fraction and nominal values in the homemade phantom showed a good correlation. The relative error remained below 14.2%. Quantification of BMC (in whole vertebra) and BMD (in spongiosa) in the ESP showed a good agreement between measured values and nominal values. The relative error remained between 0.7% and 7.5% for BMCSPECT/CT, 1.1% and 7.7% for BMCDSCT, 5.4% and 32.0 for BMDSPECT/CT, and 59.4% and 10.0% for BMDDSCT. Quantification of BMC in lumbar vertebrae 1 and 2 of a patient showed relative errors of 7.6% and -8.4% between DEXA and DSCT. Our study shows that DEQCT using a mass fraction method (phantomless) enables quantification of hydroxyapatite in a clinical nuclear medicine setting. An overestimation of the hydroxyapatite volume fraction was observed in all quantified regions, in particular in the spongiosa region of ESP. This result might be related to insufficient information about the x-ray spectra and the detector sensitivity function.
Related Concept Videos
09:36Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
03:56Bone Marrow Aspiration: A Method to Obtain Bone Marrow to Examine Cell Morphology
07:17Murine Hind Limb Long Bone Dissection and Bone Marrow Isolation
06:53Neonatal Mouse Bone Marrow Isolation and Preparation of Bone Marrow-Derived Macrophages
06:17Osteoclast Derivation from Mouse Bone Marrow