Development of drug-coated balloon for the treatment of multiple peripheral artery segments
Jordan A Anderson1, Sujan Lamichhane1, Kirby Fuglsby2
1Tailored Medical Devices, Inc, Sioux Falls, SD.
Objective:
Peripheral artery disease is the second most common cardiovascular disease. It can often occur in complex form when there is a presence of long, diffuse, and multiple lesions. Current treatments use either single long drug-coated balloons (DCBs) or multiple DCBs; however, treatment success is limited. The purpose of this study was to investigate the preclinical feasibility of our multiple-release Tailored Medical Devices DCB (MR-TMD-DCB) to treat multiple arterial segments using a single DCB.
Methods:
The MR-TMD-DCBs were developed using a two-layer coating approach. The DCBs were developed in a certified Current Good Manufacturing Practices facility using presterilized materials and reagent and then characterized for coating morphology, thermal and chemical changes, and in vitro particulate shedding. The drug loss, tissue uptake, and undelivered drug amounts were analyzed using an in vitro peripheral artery flow model and explanted pig arteries. Then, an in vivo survival study was performed using a healthy porcine model to measure the short-term drug uptake (seven swine; 14 treatments at day 1) and retention (seven swine; 14 treatments at day 7) in two different arterial segments after treatment with a single MR-TMD-DCB.
Results:
The coating on the MR-TMD-DCB was smooth and homogeneous with paclitaxel molecularly dispersed in its amorphous state. A negligible number of particulates were shed from the MR-TMD-DCB coating. A similar amount of drug was accurately delivered into two separate explanted arteries using a single MR-TMD-DCB during the in vitro flow model testing (707 ± 109 ng/mg in the first explanted artery and 783 ± 306 ng/mg in the second explanted artery). The MR-TMD-DCB treatment resulted in equivalent drug amounts in the two arterial segments at day 1 (63 ± 19 ng/mg in the first treatment site and 59 ±19 ng/mg in the second treatment site) and at day 7 (9 ± 6 ng/mg in the first treatment site and 10 ± 6 ng/mg in the second treatment site). In addition, the drug levels at each time point were in the clinically relevant range to prevent neointimal hyperplasia.
Conclusions:
The MR-TMD-DCBs provided equivalent and clinically relevant drug retention levels into two different arterial segments. Thus, MR-TMD-DCBs can be used to accurately deliver drug into multiple arterial segments with the use of a single DCB. The clinical outcomes of these findings need further investigation. Future long-term pharmacokinetics and safety studies will be performed to evaluate the safety and efficacy of the MR-TMD-DCB.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
09:14The Rabbit Model of Accelerated Atherosclerosis: A Methodological Perspective of the Iliac Artery Balloon Injury
Published on: October 3, 2017
Related Concept Videos
06:53A Rat Carotid Artery Pressure-Controlled Segmental Balloon Injury with Periadventitial Therapeutic Application
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
09:14The Rabbit Model of Accelerated Atherosclerosis: A Methodological Perspective of the Iliac Artery Balloon Injury
09:41Vascular Balloon Injury and Intraluminal Administration in Rat Carotid Artery
06:13The Intra-Aortic Balloon Pump
Bioequivalence of Drugs: Drugs with Multiple Indications