Related Experiment Video
Updated: Jan 19, 2026

Multifocal Electroretinograms
Published on: December 4, 2011
Individual multi-catheter mould technique in high-dose-rate brachytherapy - personalized approach in treating
Marta Szlag1, Piotr Wojcieszek2, Sylwia Kellas-Ślęczka2
1Radiotherapy Planning Department, Cancer Center and Institute of Oncology Gliwice Branch, Gliwice, Poland.
Purpose:
The aim of this study was to report individual surface mould multi-catheter high-dose-rate (IMM HDR) application as a salvage treatment for a head and neck angiosarcoma patient, previously treated with surgery followed by external beam radiotherapy.
Material And Methods:
A 74-year-old male reported to our center with an uncommon malignant neoplasm of blood vessels. The patient was qualified for a wide local excision (WLE) of tumor with simultaneous reconstruction using a free-flap collected from the patient's thigh. After surgery, the patient was qualified for adjuvant external-beam radiotherapy (EBRT). Volumetric arc therapy (VMAT; RapidArc®, Varian Medical Systems) was used to deliver 52.8 Gy/1.6 Gy in 33 fractions. Overall treatment time was 51 days. Six months after radiotherapy, an incisional biopsy of non-healing ulcer of the nasal bridge revealed angiosarcoma. Wide local excision with skin graft reconstruction was planned. Due to multifocal disease and lack of possibility for further margin, the resection surgery was completed after skin graft reconstruction from the right thigh. Surface IMM HDR was considered as an alternative option for further treatment. Total dose of 48 Gy (12 fractions) was planned.
Results:
One month after surface IMM HDR, healing process of the skin was observed in the treated regions and six months later, the irradiated areas recovered. General condition of the patient deteriorated two years after diagnosis and one year after HDR. He was hospitalized to receive palliative care.
Conclusions:
HDR brachytherapy may be a valuable option for angiosarcoma treatment. Difficult lesion location may yield non-radical surgery. Surface IMM HDR provides highly conformal plan and allow adjusting the dose to individual clinical situation.
Related Concept Videos
16:49Multifocal Electroretinograms
Maslow's Humanistic Approach on Personality
06:27A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
07:47Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
06:31Precision Implementation of Minimal Erythema Dose (MED) Testing to Assess Individual Variation in Human Inflammatory Response