Related Experiment Video
Updated: Jan 19, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Design and testing of microbubble-based MRI contrast agents for gastric pressure measurement
Edwin Abdurakman1,2, Martin Bencsik1, Gareth W V Cave3
1Department of Physics & Mathematics, School of Science & Technology, Nottingham Trent University, Nottingham, United Kingdom.
Purpose:
This work demonstrates specifically tailored microbubble-based preparations and their suitability as MRI contrast agents for ingestion and measuring temporal and spatial pressure variation in the human stomach.
Methods:
Enhanced alginate spheres were prepared by incorporating gas-filled microbubbles into sodium alginate solution followed by the polymerization of the mixture in an aqueous calcium lactate solution. The microbubbles were prepared with a phospholipid shell and perfluorocarbon gas filling, using a mechanical cavitational agitation regime. The NMR signal changes to externally applied pressure and coming from the enhanced alginate spheres were acquired and compared with that of alginate spheres without microbubbles. In vivo investigations were also carried out on healthy volunteers to measure the pressure variation in the stomach.
Results:
The MR signal changes in the contrast agent exhibits a linear sensitivity of approximately 40% per bar, as opposed to no measurable signal change seen in the control gas-free spheres. This novel contrast agent also demonstrates an excellent stability in simulated gastric conditions, including at body temperature. In vivo studies showed that the signal change exhibited in the meal within the antrum region is between 5% and 10%, but appears to come from both pressure changes and partial volume artifacts.
Conclusion:
This study demonstrates that alginate spheres with microbubbles can be used as an MRI contrast agent to measure pressure changes. The peristaltic movement within the stomach is seen to substantially alter the overall signal intensity of the contrast agent meal. Future work must focus on improving the contrast agent's sensitivity to pressure changes.
More Related Videos
06:10Injection of Microbubbles into Isolated Mouse Embryos: A Technique to Deliver Microbubble Contrast Agents into the Vasculature of Living Murine Embryos
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
06:10Injection of Microbubbles into Isolated Mouse Embryos: A Technique to Deliver Microbubble Contrast Agents into the Vasculature of Living Murine Embryos
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation (SHAPE) Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
11:38In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
06:54MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
07:15In vivo Macrophage Imaging Using MR Targeted Contrast Agent for Longitudinal Evaluation of Septic Arthritis