Related Experiment Video
Updated: Jan 19, 2026

Seldinger Technique Based Pulmonary Artery Catheterization: A Procedure to Insert Pulmonary Artery Catheter Through the Jugular Vein in a Porcine Model
Internal Jugular Vein as Alternative Access for Implantation of a Wireless Pulmonary Artery Pressure Sensor
Jacob Abraham1, Patrick McCann2, Lian Wang1
1Center for Cardiovascular Analytics, Research and Data Science (CARDS), Providence Heart Institute, Providence St Joseph Health, Portland, OR (J.A., L.W., J.R., D.W., R.L., K.C., K.J.S.).
Background:
A wireless pulmonary artery pressure sensor (CardioMEMS) is approved for implantation via the femoral vein. The internal jugular vein (IJ) is an attractive alternative access route commonly used in pulmonary artery catheterization.
Methods And Results:
Retrospective chart review was performed for all sensor implants from 10 providers at 4 centers from September 2016 to June 2018. To compare procedural outcomes and discharge efficiency between groups, multivariate analyses incorporating potential confounders were performed. Seventy-three (28%) patients had femoral access, and 189 (72%) had IJ access; demographics were similar between the groups. Complications, including one case of hematoma and 4 cases of mild hemoptysis, and 30-day mortality (2%-3%) did not differ between groups. Provider preference for IJ access substantially increased over time, with IJ accounting for 90% of cases in 2018. After risk-adjustment, IJ cases had 20% (5%-33%) shorter fluoroscopy time (P=0.01) and 24% (7%-38%) lower contrast volume (P=0.008). Compared with outpatient femoral cases, outpatient IJ cases had 62% (52%-69%) faster needle-to-door time and were 34 times (6-235) more likely to have same-day discharge (P<0.001 for both).
Conclusions:
IJ access for CardioMEMS implant is a safe alternative associated with superior procedural and discharge outcomes. Implanters at 4 high-volume centers adopted IJ access as the preferred implant approach.
Related Concept Videos
02:50Seldinger Technique Based Pulmonary Artery Catheterization: A Procedure to Insert Pulmonary Artery Catheter Through the Jugular Vein in a Porcine Model
Central Venous Catheter Insertion: Internal Jugular
Central venous access is necessary in a multitude of clinical situations, including vascular access, vasopressor and caustic medication delivery, central venous pressure monitoring, intravascular device delivery (pacing wires, Swann-Ganz catheters), volume resuscitation, total parental nutrition, hemodialysis, and frequent phlebotomy.
Safe reliable placement of a central venous catheter (CVC) in...
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:27Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
07:11Establishment and Validation of a Rat Model of Pulmonary Arterial Hypertension Associated with Pulmonary Fibrosis
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
