Internal Jugular Vein as Alternative Access for Implantation of a Wireless Pulmonary Artery Pressure Sensor

Jacob Abraham1, Patrick McCann2, Lian Wang1

  • 1Center for Cardiovascular Analytics, Research and Data Science (CARDS), Providence Heart Institute, Providence St Joseph Health, Portland, OR (J.A., L.W., J.R., D.W., R.L., K.C., K.J.S.).

Circulation. Heart Failure
|September 17, 2019
PubMed
Abstract

Related Concept Videos

Seldinger Technique Based Pulmonary Artery Catheterization: A Procedure to Insert Pulmonary Artery Catheter Through the Jugular Vein in a Porcine Model02:50

Seldinger Technique Based Pulmonary Artery Catheterization: A Procedure to Insert Pulmonary Artery Catheter Through the Jugular Vein in a Porcine Model

In this video, we have demonstrated a step-by-step procedure of pulmonary artery catheterization by inserting an intravascular catheter through jugular vein and reach the pulmonary artery to measure the cardiac chamber pressure in porcine...
3.5K
Central Venous Catheter Insertion: Internal Jugular11:39

Central Venous Catheter Insertion: Internal Jugular

Source: James W Bonz, MD, Emergency Medicine, Yale School of Medicine, New Haven, Connecticut, USA
Central venous access is necessary in a multitude of clinical situations, including vascular access, vasopressor and caustic medication delivery, central venous pressure monitoring, intravascular device delivery (pacing wires, Swann-Ganz catheters), volume resuscitation, total parental nutrition, hemodialysis, and frequent phlebotomy.
Safe reliable placement of a central venous catheter (CVC) in...
46.9K
Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

The manuscript presents a miniature implantable pH sensor with ASK modulated wireless output together with a fully passive receiver circuit based on zero-bias Schottky diodes. This solution can be used as a basis in the development of in vivo calibrated electrostimulation therapy devices and for ambulatory pH...
2.9K
Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.08:27

Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.

We describe a method for creating a reliable model of cerebral venous hypertension in the adult mouse. This model has been widely described and tested in the rat. This new counterpart in the mice opens the possibility of using genetic modified animals and thereby broadens the applications of the...
14.7K
Establishment and Validation of a Rat Model of Pulmonary Arterial Hypertension Associated with Pulmonary Fibrosis07:11

Establishment and Validation of a Rat Model of Pulmonary Arterial Hypertension Associated with Pulmonary Fibrosis

Here, the method of inducing pulmonary arterial hypertension associated with pulmonary fibrosis (PF-PH) rat model by injecting bleomycin into the airway is introduced. We also provide a step-by-step approach to validate this animal...
872
Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model09:05

Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model

Vascular accesses to measure hemodynamics, provide fluids and perform blood sampling are important to any small animal model study. We present a technique for implanting catheters into the carotid artery and the common jugular vein in an anesthetized rat for connecting to a system to perform monitoring, infusions and...
74.4K