Related Experiment Video
Updated: Jan 19, 2026

Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
Development of an international external quality assurance program for HIV-1 incidence using the Limiting Antigen
Sheila M Keating1,2, Wes Rountree3, Eduard Grebe1,2
1Vitalant Research Institute, San Francisco, CA, United States of America.
Abstract:
Laboratory assays for identifying recent HIV-1 infections are widely used for estimating incidence in cross-sectional population-level surveys in global HIV-1surveillance. Adequate assay and laboratory performance are required to ensure accurate incidence estimates. The NIAID-supported External Quality Assurance Program Oversight Laboratory (EQAPOL) established a proficiency testing program for the most widely-used incidence assay, the HIV-1 Limiting Antigen Avidity EIA (LAg), with US Centers for Disease Control and Prevention (CDC)-approved kits manufactured by Sedia Biosciences Corporation and Maxim Biomedical. The objective of this program is to monitor the performance of participating laboratories. Four rounds of blinded external proficiency (EP) panels were distributed to up to twenty testing sites (7 North American, 5 African, 4 Asian, 2 South American and 2 European). These panels consisted of ten plasma samples: three blinded well-characterized HIV-1-seropositive samples that were included as replicates and an HIV-negative control. The seropositive samples spanned the dynamic range of the assay and are categorized as either recent or long-term infection. Participating sites performed the assay according to manufacturers' instructions and completed an online survey to gather information on kit manufacturer, lot of kit used, laboratory procedures and the experience of technicians. On average, fifteen sites participated in each round of testing, with an average of four sites testing with only the Maxim assay, seven testing with only the Sedia assay and five sites utilizing both assays. Overall, the Sedia and Maxim assays yielded similar infection status categorization across the laboratories; however, for most of the nine HIV+ samples tested, there were significant differences in the optical density readouts, ODn (N = 8) and OD (N = 7), between LAg kit manufacturers (p < 0.05 based on mixed effects models. The EQAPOL LAg program is important for monitoring laboratory performance as well as detecting variations between manufacturers of HIV-1incidence assays.
Related Concept Videos
13:58Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Quality Assurance
19:57An Affordable HIV-1 Drug Resistance Monitoring Method for Resource Limited Settings
Affinity and Avidity
10:18Amplification of Near Full-length HIV-1 Proviruses for Next-Generation Sequencing
11:10Genotypic Inference of HIV-1 Tropism Using Population-based Sequencing of V3
