Related Experiment Video
Updated: Jan 19, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Fractional flow reserve-based 4D hemodynamic simulation of time-resolved blood flow in left anterior descending
Yinghong Zhao1, Jie Ping2, Xianchao Yu3
1Xuzhou Medical University, 209, Tongshan Road, Yunlong District, Xuzhou, Jiangsu, China.
Background:
The purpose of this study was to investigate the feasibility of the non-invasive assessment of hemodynamic parameters with computational fluid dynamics in left anterior descending coronary artery based on invasive fractional flow reserve.
Methods:
A left coronary artery model based on computed tomography angiography was reconstructed using MIMICS 18.0 for computational fluid dynamics analysis. With actual fractional flow reserve measured from the patient, 4D hemodynamic profiles of time-resolved blood flow were simulated.
Findings:
The 4D blood flow simulation could provide extensive information of blood flow status. Hemodynamic parameters, such as velocity, wall shear stress and pressure were simulated throughout the cardiac cycle. There might be high flow velocities and high wall shear stress in the stenotic region throughout the whole cycle, both of which peaked in the case of the maximum inlet differential pressure. The reverse flow and vortex were detectable at the downstream areas beneath the stenotic site. The pressure remarkably increased near the proximal stenotic end and declined in the mid-stenosis. Moreover, the simulation results provided detailed and accurate mass flow measurements of hemodynamic parameters as well.
Interpretation:
The computational fluid dynamics analysis of 4D blood flow based on fractional flow reserve is feasible in left anterior descending coronary artery. It presents the merits of providing both qualitative and quantitative information for further investigation of the links between hemodynamic parameters and left anterior descending artery stenosis.
More Related Videos
06:32Evaluation of Coronary Flow Reserve After Myocardial Ischemia Reperfusion in Rats
Published on: June 28, 2019
09:37Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
Published on: December 2, 2014
Related Concept Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
06:32Evaluation of Coronary Flow Reserve After Myocardial Ischemia Reperfusion in Rats
09:37Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
05:07Dynamic Assessments of Coronary Flow Reserve after Myocardial Ischemia Reperfusion in Mice
07:55Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
08:38Murine Myocardial Infarction Model using Permanent Ligation of Left Anterior Descending Coronary Artery