Related Experiment Video
Updated: Jan 19, 2026

Planar Gradient Diffusion System to Investigate Chemotaxis in a 3D Collagen Matrix
Published on: June 12, 2015
Investigating Potential Limitations of Current Diffusive Gradients in Thin Films (DGT) Samplers for Measuring Organic
Runmei Wang1, Yitao Zou2, Jun Luo2
1Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom.
Abstract:
The diffusive gradients in thin films (DGT) passive sampler has emerged as a powerful tool for measuring in situ concentrations of organic contaminants in waters with appropriate spatial and temporal resolution at low cost. This study addresses the property range of compounds which can be routinely sampled with the present design of DGT device. Sorption experiments and DGT deployment with 9 model chemicals [organophosphate esters with a wide range of log KOW (0.8-9.5), molecular weight (182-435 Da)] and different functional groups showed compounds with high hydrophobicity and aromatic rings are prone to retention on membrane filters, which slows the supply of chemical to the binding resin of the sampler. The current DGT sampler (PTFE membrane filter, agarose gel diffusion layer, and HLB binding layer) is potentially reliable for measuring hydrophilic [log KOW (0.8-2.6)] and nonaromatic-ring chemicals. For compounds of higher values of KOW or with aromatic rings, knowledge of the lag phase is necessary to optimize sampling times to avoid biasing subsequent laboratory analyses. A standard procedure is used to measure lag times (from minutes to days) by exposing a series of DGT samplers in waters until linear mass accumulation in samplers is achieved. We discuss how monitoring of a wide array of organic contaminants across classes should be possible in the future with a range of validated new DGT devices, optimized for the choice of membrane filter, diffusive material, and binding resin.
Related Concept Videos
09:26Planar Gradient Diffusion System to Investigate Chemotaxis in a 3D Collagen Matrix
12:22Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
08:26Spray-Coated Melanin/PEDOT:PSS Films for Sustainable Organic Electrochemical Transistors
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
11:23Polydimethylsiloxane-polycarbonate Microfluidic Devices for Cell Migration Studies Under Perpendicular Chemical and Oxygen Gradients

