Related Experiment Video
Updated: Jan 19, 2026

Human iPSC-Derived Cardiomyocyte Networks on Multiwell Micro-electrode Arrays for Recurrent Action Potential Recordings
Published on: July 15, 2019
Cardiotoxicity screening of illicit drugs and new psychoactive substances (NPS) in human iPSC-derived cardiomyocytes
Anne Zwartsen1, Tessa de Korte2, Peter Nacken3
1Neurotoxicology Research Group, Division Toxicology, Institute for Risk Assessment Sciences (IRAS), Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands; Dutch Poisons Information Center (DPIC), University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Abstract:
The use of recreational drugs, including new psychoactive substances (NPS), is paralleled by emergency department visits of drug users with severe cardiotoxicity. Drug-induced cardiotoxicity can be the (secondary) result of increased norepinephrine blood concentrations, but data on potential drug-induced direct effects on cardiomyocyte function are scarce. The presence of hundreds of NPS therefore calls for efficient screening models to assess direct cardiotoxicity. We investigated effects of four reference compounds (3-30 nM dofetilide, nifedipine and isoproterenol, and 1-10 μM mexiletine) and six recreational drugs (0.01-100 μM cocaine, 0.01-1000 μM amphetamine, MDMA, 4-fluoroamphetamine, α-PVP and MDPV) on cardiomyocyte function (beat rate, spike amplitude and field potential duration (FPD ≈ QT interval in ECGs)), using Pluricyte® human-induced pluripotent stem cell (hiPSC)-derived cardiomyocytes cultured on ready-to-use CardioPlate™ multi-well microelectrode arrays (mwMEAs). Moreover, the effects of exposure to recreational drugs on cell viability were assessed. Effects of reference compounds were in accordance with the literature, indicating the presence of hERG potassium (dofetilide), sodium (mexiletine) and calcium (nifedipine) channels and α-adrenergic receptors (isoproterenol). All recreational drugs decreased the spike amplitude at 10-100 μM. All amphetamine-type stimulants and α-PVP decreased the beat rate at 300 μM, while cocaine and MDPV did so at 10 μM and 30 μM, respectively. All drugs increased the FPD, however at varying concentrations. MDMA, MDPV and amphetamine affected cardiomyocyte function at concentrations relevant for human exposure, while other drugs affected cardiomyocyte function only at higher concentrations (≥ 10 μM). Cell viability was only mildly affected at concentrations well above the lowest concentrations affecting cardiomyocyte function. We demonstrate that MEA recordings of hiPSC-derived cardiomyocytes enable screening for acute, direct effects on cardiomyocyte function. Our data further indicate that tachycardia in patients exposed to recreational drugs is likely due to indirect drug effects, while prolonged repolarization periods (prolonged QTc interval) could (partly) result from direct drug effects on cardiomyocyte function.
More Related Videos
10:30Technical Applications of Microelectrode Array and Patch Clamp Recordings on Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes
Published on: August 4, 2022
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Related Concept Videos
08:53Human iPSC-Derived Cardiomyocyte Networks on Multiwell Micro-electrode Arrays for Recurrent Action Potential Recordings
10:30Technical Applications of Microelectrode Array and Patch Clamp Recordings on Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes (hPSC-CMs) Using Multi-electrode Arrays (MEAs)
10:01High-Throughput Optical Controlling and Recording Calcium Signal in iPSC-Derived Cardiomyocytes for Toxicity Testing and Phenotypic Drug Screening
14:03High-Throughput Cardiotoxicity Screening Using Mature Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Monolayers
02:56Ultrasound-Induced Neuromodulation Using a Microelectrode Array System