Related Experiment Video
Updated: Jan 19, 2026

Cultivate Primary Nasal Epithelial Cells from Children and Reprogram into Induced Pluripotent Stem Cells
Published on: March 10, 2016
Virus-Induced Asthma/Wheeze in Preschool Children: Longitudinal Assessment of Airflow Limitation Using Impulse
George N Konstantinou1,2, Nikolaos G Papadopoulos3,4, Emmanouel Manousakis3
1General Military Training Hospital, 56429 Thessaloniki, Greece. gnkonstantinou@gmail.com.
Insights
Impulse Oscillometry System (IOS) can objectively assess airflow limitation in young children during wheezing episodes. Individualized lung function monitoring using IOS parameters like R5 is feasible, reproducible, and aids in diagnosing reversible airway obstruction.
Area of Science:
- Pediatric Pulmonology
- Respiratory Physiology
- Diagnostic Tools
Background:
- Impulse Oscillometry System (IOS) is used for respiratory disease assessment in children.
- Previous studies lacked individualized analysis of IOS parameter fluctuations.
- Understanding longitudinal changes in IOS parameters during wheezing is crucial.
Purpose of the Study:
- To longitudinally evaluate changes in airflow limitation and bronchodilator responsiveness using IOS in young children during virus-induced wheezing.
- To assess the feasibility, reproducibility, and diagnostic properties of IOS parameters (R5, R20).
- To investigate individualized fluctuations in IOS parameters.
Main Methods:
- Prospective two-year study involving steroid-naïve four- to six-year-old children.
- Lung function assessed using IOS every six weeks, at the onset of wheezing (Day 0), and at 10 and 30 days post-episode.
- Analysis of pulmonary resistance parameters (R5, R20) and bronchodilator response (ΔR5).
Main Results:
- IOS measurements were feasible and highly reproducible in preschoolers.
- R5 values decreased significantly during wheezing episodes, returning to baseline within 10 days.
- Bronchodilator response (ΔR5) was more pronounced during wheezing, with specific thresholds indicating reversible obstruction.
Conclusions:
- IOS is a valuable, objective, and reproducible tool for assessing airflow limitation and bronchodilator response in young children.
- Individualized monitoring of IOS parameters, especially R5, is reliable for tracking lung function changes.
- IOS can aid in diagnosing reversible airway obstruction in preschool children with wheezing.
Abstract:
: Several researchers have assessed the utility of Impulse Oscillometry System (IOS) in diagnosing and evaluating the severity of respiratory diseases in childhood, but none has investigated the impact of the fluctuations of IOS parameters in an individualized manner. In this two-year prospective study, we aimed to longitudinally evaluate changes in airflow limitation and bronchodilator responsiveness in steroid-naïve four- to six-year-old children during a virus-induced wheezing episode, with IOS pulmonary resistance parameters set at 5 (R5) and 20 (R20) Hz. Moreover, feasibility and reproducibility, in addition to the diagnostic properties of these parameters were examined. Lung function was assessed every six weeks (baseline), within the first 48 hours following an acute wheezing episode (Day 0), after 10, and after 30 days. Forty-three out of 93 recruited children (4.5 ± 0.4 years old) experienced a wheezing episode during the study period. All children were able to perform the IOS effort in an acceptable and highly reproducible manner. R5 and R20 fluctuated independently of atopy, age, height, and weight. On Day 0, R5 values were significantly lower than the respective baseline values and returned to individual baseline levels within 10 days. Post-bronchodilation R5 values were similar to the baseline ones, reflecting a reversible airway obstruction on Day 0. Response to bronchodilation (ΔR5) was significantly more pronounced on Day 0. ΔR5 values lower than -20.5% had a sensitivity of 70% and a specificity of 76% and could accurately identify up to 75% of the examined preschoolers. This study provides evidence in favor of the objective utility of IOS as an easy, highly reproducible, and sensitive technique to assess clinically significant fluctuations and bronchodilation responses suggestive of airflow limitation. Reference values although necessary are suboptimal, utilizing the personal best values as personal reference is useful and reliable.
Related Concept Videos
12:08Cultivate Primary Nasal Epithelial Cells from Children and Reprogram into Induced Pluripotent Stem Cells
14:49Conducting Respiratory Oscillometry in an Outpatient Setting
Toddler and Preschool Child Exam
The key to a successful exam of a toddler or preschool-age child is building rapport and trust between them and the provider. Toddlers, in particular, may be wary of strangers and unwilling to cooperate with the physical exam, which is expected age-appropriate behavior. In order to provide good care and create a comfortable patient experience, clinicians need to tailor their interaction to the child's developmental...
09:12Three Laboratory Procedures for Assessing Different Manifestations of Impulsivity in Rats
09:05Assessing Working Memory in Children: The Comprehensive Assessment Battery for Children – Working Memory (CABC-WM)
07:44Assessment of Cerebral Lateralization in Children using Functional Transcranial Doppler Ultrasound (fTCD)