Related Experiment Video
Updated: Jan 19, 2026

Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
Published on: July 12, 2024
Fibrosis-4 index reflects right-sided filling pressure in patients with heart failure
Daichi Maeda1, Kazushi Sakane1, Takahide Ito1
1Department of Cardiology, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, Osaka, 569-8686, Japan.
Abstract:
The fibrosis-4 index (FIB-4 index) is a marker of liver fibrosis. It has been reported that the FIB-4 index in compensated phase is associated with estimated right-sided filling pressure and poor prognosis in patients with heart failure. However, the relationship with invasively obtained right-sided cardiac pressures has been unclear. Hemodynamic status was evaluated by right heart catheterization in 189 heart failure patients who were in a clinically compensated phase between January 2015 and September 2017. Patients were assigned to two groups based on a median FIB-4 index of 2.15, then hemodynamic parameters and event rates were compared. Endpoint was defined as a composite of all-cause death, readmission for heart failure, or left ventricular-assist device implantation. Then, we also investigated correlations between the FIB-4 index and clinical factors, including hemodynamic parameters. Patients with a high FIB-4 index were significantly older (76 [IQR, 63-80] vs. 65 [IQR, 56-74] years, P < 0.001) and had higher right atrial pressure (RAP; 7 [IQR, 5-11] vs. 4 [IQR, 1-6] mmHg, P < 0.001) and pulmonary capillary wedge pressure (16 [IQR, 12-22] vs. 12 [IQR, 8-19] mmHg, P = 0.011) than those with a low FIB-4 index. The FIB-4 index correlated more strongly with parameters of right-sided than left-sided HF (RAP, R = 0.41, P < 0.001; inferior vena cava diameter, R = 0.44, P < 0.001; pulmonary capillary wedge pressure, R = 0.15, P = 0.038; brain natriuretic peptide, R = 0.14, P = 0.29). Multiple regression analysis showed that the FIB-4 index independently correlated with RAP. In conclusion, the FIB-4 index can non-invasively reflect right-sided filling pressure, which might explain why it is associated with a poor prognosis, among patients with heart failure.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
07:13A Rat Model of Pressure Overload Induced Moderate Remodeling and Systolic Dysfunction as Opposed to Overt Systolic Heart Failure
Published on: April 30, 2020
Related Concept Videos
03:47Workflow and Framework for Collecting and Implementing Point-of-Care Ultrasound Data in the Management of Heart Failure Patients
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
07:13A Rat Model of Pressure Overload Induced Moderate Remodeling and Systolic Dysfunction as Opposed to Overt Systolic Heart Failure
07:09A Surgical Model of Heart Failure with Preserved Ejection Fraction in Tibetan Minipigs
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
04:05Clinical Application of Phase Angle and BIVA Z-Score Analyses in Patients Admitted to an Emergency Department with Acute Heart Failure