Measurement of isocenter alignment accuracy and image distortion of an 0.35 T MR-Linac system

S Dorsch1, P Mann, A Elter

  • 1Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), INF 280, 69120 Heidelberg, Germany. Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany. National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany. Author to whom correspondence should be addressed.

Related Concept Videos

Measuring the Complete-arch Distortion of an Optical Dental Impression06:51

Measuring the Complete-arch Distortion of an Optical Dental Impression

Here, we present a protocol to measure the degree of distortion at each part of the compete-arch digital impression acquired from an intraoral scanner with 3D-printed metal phantom with standard...
8.0K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.0K
Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision07:57

Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision

Accuracy is a major demand in dental medicine. To verify accuracy, reference scanners are needed. This article presents a new reference scanner with an adjusted scanning method to acquire a broad variety of dental morphologies with high trueness and...
13.9K
Fluorescence Imaging with One-nanometer Accuracy (FIONA)11:56

Fluorescence Imaging with One-nanometer Accuracy (FIONA)

Single fluorophores can be localized with nanometer precision using FIONA. Here a summary of the FIONA technique is reported, and how to carry out FIONA experiments is...
18.2K
Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration07:03

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

This article describes the design and development of a sterilizable custom camera optical distortion calibration target for the peri-operative, fluid-immersed calibration of endoscopes during endoscopic...
8.0K
Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K