Related Experiment Video
Updated: Jan 19, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Modelling the radioluminescence of Sm2+ and Sm3+ in the dosimeter material NaMgF3:Sm
J J Schuyt1, J Donaldson1, G V M Williams1
1The MacDiarmid Institute for Advanced Materials and Nanotechnology, SCPS, Victoria University of Wellington, PO Box 600, Wellington 6140, New Zealand.
Abstract:
Photoluminescence (PL) and radioluminescence (RL) measurements were made on NaMgF3:Sm before, during and after exposure to high doses of ionising radiation. Magnetic measurements prior to irradiation showed that approximately 10% of the total Sm concentration was in the divalent state. The RL from Sm3+ was found to increase while the Sm2+ RL decreased with increasing x-ray dose before reaching steady-state values for high doses. This behaviour is opposite to that previously reported for Sm3+ and Sm2+ PL. We show that this apparent discrepancy can be accounted for by a RL model where there is a hole trap, an electron trap, and direct x-ray induced carrier recombination at Sm2+ and Sm3+. Furthermore, a good fit to the dose-dependence of all of the Sm RL emissions can be obtained by assuming that the relevant electron and hole traps are close to Sm3+. Our model accounts for F3-centre production during irradiation that affects some of the Sm3+ RL emissions via reabsorption of the RL by the F3-centres. Thus, the rate of F3-centre production can be conveniently monitored by the RL intensity ratio, I RL(567 nm)/I RL(650 nm). Additionally, the Sm2+ RL emissions may be expressed as [1.94 × I RL(721 nm)] - I RL(695 nm) to determine the real-time dose rate, independent of dose history.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
03:54A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance
Published on: October 19, 2018
Related Concept Videos
06:43Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Material Constants
In contrast to the production of cars or toasters, where millions of identical copies are made and extensive prototype testing is possible, each civil engineering structure is unique and very expensive to reproduce (Fig.1). Therefore, civil engineers must extensively rely on analytical modeling to design their structures. These models are simplified abstractions of reality and are used to...
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material
03:54A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance