Related Experiment Video
Updated: Jan 19, 2026

Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Effect of gallic acid addition on some mechanical properties of self-adhesive resin cements
Bebek Serra Oguz Ahmet1, Gulsum Sayin Ozel1, Mustafa Murat Mutluay2
1Istanbul Medipol University, School of Dentistry, Department of Prosthodontics, Istanbul, Turkey.
Abstract:
Self-adhesive resin cements (RCs) activate matrix metalloproteinase (MMP) and cathepsin-related collagen degradation, and gallic acid (GA) inhibits the activity of both MMPs and cysteine cathepsins. The purpose of this study was to evaluate the setting time, biaxial flexural strength, and Vickers hardness of self-adhesive RCs after the addition of two different concentrations of GA. RelyX U200 (3M ESPE) and Panavia SA (Kuraray) were modified with 0.5 and 1 wt% GA. The setting time of five samples in each RC group was assessed using a thermocouple apparatus as described in the ISO 4049 test. Biaxial flexure strength was measured using a universal testing machine until failure. Vickers hardness was measured with three randomized indentations on the surface of each resin disc. RCs without GA were used as control. Data were analyzed using a one-way analysis of variance and Tukey's HSD test (α = 0.05). The setting times ranged from 2.4 to 4.6 min for RelyX and from 4.9 to 6.0 min for Panavia. The biaxial flexure strength ranged from 76.5 to 109.7 MPa for RelyX and from 73.3 to 108.2 MPa for Panavia. Vickers hardness values ranged from 41.6 to 58.6 for RelyX and 27.2 to 33.6 for Panavia. The addition of 0.5 and 1 wt% GA to improve durability of resin-dentin bonds had no adverse effects on setting time, whereas the biaxial flexure strength and Vickers hardness values for the tested materials were significantly reduced.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
10:24Quantifying the Mechanical Properties of the Endothelial Glycocalyx with Atomic Force Microscopy
Published on: February 21, 2013
Related Concept Videos
Nucleophilic Addition to the Carbonyl Group: General Mechanism
A stronger nucleophile can directly attack the electrophilic center, the carbonyl carbon. The HOMO orbital of the nucleophile interacts with the LUMO (π* antibonding) orbital present on the carbonyl carbon. This interaction breaks the π bond and shifts the π...
09:54Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Acid-Catalyzed Aldol Addition Reaction
Physical Properties of Carboxylic Acids
Radical Anti-Markovnikov Addition to Alkenes: Mechanism
The mechanism starts with chain initiation, which involves two steps. In the first chain initiation step, a weak peroxide bond is homolytically cleaved upon mild heating to form two alkoxy radicals. In the second initiation step, a hydrogen atom is abstracted by the alkoxy...