Related Experiment Video
Updated: Jan 19, 2026

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
99mTc-MIBI SPECT/CT imaging had high sensitivity in accurate localization of parathyroids before parathyroidectomy
Ming Zeng1, Wei Liu2, Xiaoming Zha3
1Department of Nephrology, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital , Nanjing , China.
Abstract:
Purpose: Accurate preoperative parathyroid localization is important for successful parathyroidectomy (PTX). The aim of our study was to investigate whether SPECT/CT has enhanced effect in preoperative localization of parathyroids. Methods: In our retrospective cohort study, we evaluated the effects of technetium-99m methoxyisobutylisonitrile-single-photon emission computed tomography/computed tomography (99mTc-MIBI SPECT/CT) on preoperative parathyroid localization for 645 secondary hyperparathyroidism (SHPT) patients. Among them, 569 successful PTX patients were divided into group A (received 99mTc-MIBI scintigraphy, n = 175) and group B (received 99mTc-MIBI scintigraphy and SPECT/CT imaging, n = 394). Sensitivity, specificity, and consistency of two imaging methods in preoperative localization of parathyroids were compared. Results: Overall sensitivity and consistency were higher in group B, while there was no difference in specificity between the two groups. In group A, the sensitivity of 99mTc-MIBI was 50.00%, 77.11%, 61.76%, and 76.54% in the right upper gland (RU), right lower gland (RL), left upper gland (LU), and left lower gland (LL) subgroups, while the consistency was 52.00%, 76.57%, 61.71%, and 75.43%, respectively. In group B, the sensitivity of 99mTc-MIBI with SPECT/CT was 69.39%, 90.03%, 78.07%, and 84.27%, and the consistency was 69.54%, 88.32%, 78.43%, and 84.26%, respectively. The sensitivity and consistency in lower glands were higher than in upper glands in both groups. Sensitivity for eutopic parathyroid was higher in group B, while there was no difference for ectopic parathyroid. Conclusions: 99mTc-MIBI SPECT/CT can increase the sensitivity and consistency of preoperative localization of eutopic parathyroid glands, and it can accurately locate ectopic parathyroid without sensitivity improvement.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography

