Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations
Oliver Husser1, Costanza Pellegrini2, Won-Keun Kim3
1Klinik für Innere Medizin I, Kardiologie, St. Johannes-Hospital Dortmund, Dortmund, Germany.
Objectives:
This study sought to evaluate the impact of the ACURATE neo (NEO) (Boston Scientific, Marlborough, Massachusetts) versus SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) on permanent pacemaker implantation (PPI) in patients with pre-existing right bundle branch block (RBBB) after transcatheter aortic valve replacement.
Background:
Pre-existing RBBB is the strongest patient-related predictor for PPI after transcatheter aortic valve replacement. No comparison of newer-generation transcatheter heart valves with regard to PPI in these patients exists.
Methods:
This multicenter registry includes 4,305 patients; 296 (6.9%) had pre-existent RBBB and no pacemaker at baseline and formed the study population. The primary endpoint was new PPI at 30 days. The association of NEO versus S3 with PPI was assessed using binary logistic regression analyses and inverse probability treatment weighting in a propensity-matched population.
Results:
The 30-day PPI rate was 39.2%. The S3 and NEO were used in 66.9% and 33.1%, respectively. The NEO was associated with lower rates of PPI compared with the S3 (29.6% vs. 43.9%; p = 0.025; odds ratio [OR]: 0.54; 95% confidence interval [CI]: 0.32 to 0.89; p = 0.018), after multivariable adjustment (OR: 0.48; 95% CI: 0.26 to 0.86; p = 0.014), and in the inverse probability treatment weighting analysis (OR: 0.37; 95% CI: 0.25 to 0.55; p < 0.001). There was no difference in device failure (8.2% vs. 6.6%; p = 0.792) or in-hospital course. In the propensity-matched population, PPI rate was also lower in the NEO versus S3 (23.1% vs. 44.6%; p = 0.016; OR: 0.37; 95% CI: 0.17 to 0.78; p = 0.010), with no difference in device failure (9.2% vs. 6.2%; p = 0.742).
Conclusions:
In patients with RBBB, risk of PPI was significantly lower with the NEO compared with the S3, suggesting the possibility of a patient tailored transcatheter heart valve therapy.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis III: Medical Management
Cardiomyopathy V: Interprofessional Care
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Valve Prolapse II: Assessment and Management