Related Experiment Video
Updated: Jan 19, 2026

Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Trends of Cardiovascular Implantable Electronic Device Infection in 3 Decades: A Population-Based Study
Mingyan Dai1, Cheng Cai2, Vaidya Vaibhav3
1Department of Cardiology, Renmin Hospital of Wuhan University, Cardiovascular Research Institute, Wuhan University, Hubei Key Laboratory of Cardiology, Wuhan, Hubei, China; Department of Cardiovascular Medicine, Mayo Clinic College of Medicine and Science, Rochester, Minnesota.
Objectives:
This study assessed trends in the incidence of cardiovascular implantable electronic device (CIED) infection in the last 3 decades using a population-based records linkage study.
Background:
Infection remains an important issue associated with increased implantation rate and dwell time of CIEDs.
Methods:
We identified a cohort of all adults with CIEDs who resided in Olmsted County, Minnesota, from 1988 to 2015, using the medical linkage system of the Rochester Epidemiology Project. Standardized criteria were used to identify all CIED infection cases. The cumulative rate of CIED infection was estimated using the Kaplan-Meier method, and the trends of CIED infection incidence were calculated with person-years of follow-up after device implantation.
Results:
The cumulative probabilities of overall CIED infection were 6.2% (95% confidence interval [CI]: 4.0% to 8.4%) at 15 years and 11.7% (95% CI: 6.8% to 17.3%) at 25 years of follow-up. The incidence of CIED infection every 7 years from 1988 to 2015 was 1.3, 5.7, 4.1, and 4.7 per 1,000-person years, respectively. The 15-year cumulative probabilities of CIED infection after the initial, second, and third procedures were 2.6% (95% CI: 1.4% to 3.8%), 2.7% (95% CI: 1.2% to 4.2%), and 24.1% (95% CI: 3.8% to 44.4%), respectively. Generator changes (hazard ratio [HR]: 3.91; 95% CI: 1.47 to 10.37; p = 0.006) and upgrades (HR: 3.08; 95% CI: 1.24 to 7.62; p = 0.02) were significantly associated with infection.
Conclusions:
The incidence of CIED infection had a trend of increasing in the past 2 decades. Contemporary implantable cardioverter-defibrillator and cardiac resynchronization therapies and repeated manipulation of device pockets introduced a greater risk of CIED infection.
More Related Videos
07:56Monitoring Changes in Human Umbilical Vein Endothelial Cells upon Viral Infection Using Impedance-Based Real-Time Cell Analysis
Published on: May 5, 2023
06:29Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Endocarditis I: Introduction
Endocarditis III: Medical Management
Endocarditis II: Clinical Features of Infective Endocarditis
Endocarditis IV: Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...