Related Experiment Video
Updated: Jan 19, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative
C Kokoroghiannis1, D Vasilakos1, K Zisis1
15th Department of Orthopaedics, "KAT" General Hospital of Athens, Nikis 2 Str, Athens, Greece.
Purpose:
The present article reviews data from biomechanical and clinical studies which indicate that rotational instability can cause failure of fixation due to the particular characteristics of the fracture, the mechanical properties of the chosen implant or flaws in surgical technique.
Methods:
Although radiographs give a similar impression in failure of fractures fixed with cephalomedullary nails, different mechanisms involving rotation of the femoral head may play a key role.
Results:
The incidence of failure in pertrochanteric fracture fixation is decreasing as implants continue to evolve. It is possible that currently reported low failure rates do not apply equally to all subtypes of this diverse group of fractures. Since the introduction of sliding hip screws, "cut-out" due to varus collapse of the proximal fracture fragment has been the only reported mode of failure.
Conclusion:
Excessive rotation leading to eventual "cut-out" has not been adequately studied, and thus, available evidence is not sufficient to definitely prove this theoretical approach. As nailing is gradually overtaking extramedullary fixation as the treatment of choice, especially for comminuted pertrochanteric fractures which can be rotationally unstable, further research is warranted to improve our understanding of the pathogenetic mechanisms of failure.
More Related Videos
06:59Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Stability of structures
General Case of Eccentric Axial Loading