Color Doppler Duplex Ultrasound Parameters in Men Without Organic Erectile Dysfunction
Ram A Pathak1, Gregory A Broderick2
1Wake Forest University School of Medicine, Winston-Salem, North Carolina.
Objective:
To define age-specific normal Color Doppler Duplex Ultrasound (CDDU) parameters based on a large institutional database of men referred for vascular erectile testing, but found to have normal and sustained rigidity following penile injection of alprostadil.
Methods:
A retrospective review of patients who underwent CDDU from January 1, 2005 to December 31, 2014 was conducted. The indications for CDDU assessments included complaint of erectile dysfunction refractory to PDE-5 inhibitors, new-onset penile curvature, or secondary consultation for erectile dysfunction. Pearson correlation test was used to evaluate the association between ordinal age groups with peak systolic velocity (PSV) and resistive index (RI) measurements to determine the effect of age on erectile response.
Results:
A total of 2043 patients underwent CDDU from January 1, 2005 to December 31, 2014. 259 patients (12.7%) with a mean age 53.7 and a mean BMI of 27.2 were noted to have normal erectile rigidity and normal Doppler parameters (PSV >35 cm/s, RI >0.90). Prolonged erection, defined by need to inject phenylephrine reversal agent at 1-2 hours, occurred in 93% of patients. When age was categorized by decade, a negative correlation coefficient was obtained for previsual sexual stimulation PSV (-0.09, P = .164) and postvisual sexual stimulation PSV (-0.23, P = .005).
Conclusion:
In men with normal vascular erections there appears to be a significant, age-related decline in postvisual sexual stimulation PSV without compromise to cavernous venous occlusion as measured by RI. We have used Doppler parameters in patients without vascular ED to define age-specific normalcy.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Urodynamic Studies: Uroflowmetry
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Disorders of the Male Reproductive System
Prostate disorders are another major concern. These conditions can impair urinary flow due to the prostate's location around the urethra....
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...