Related Experiment Video
Updated: Jan 19, 2026

Electrostatic Method to Remove Particulate Organic Matter from Soil
Published on: February 10, 2021
The study on lead desorption from the real-field contaminated soil by circulation-enhanced electrokinetics (CEEK)
Jih-Hsing Chang1, Cheng-Di Dong2, Shih-Han Huang1
1Department of Environmental Engineering and Management, Chaoyang University of Technology, 168, Jifeng E. Rd., Wufeng District, Taichung, 41349, Taiwan.
Abstract:
This study applied a circulation-enhanced electrokinetics (CEEK) technique to remove heavy metal lead from the agricultural land. Soil samples (lead concentration around 4000 mg/kg) were collected in a certain polluted agricultural site in Nantou, Taiwan. Operational parameters of CEEK such as the voltage gradient (1.0 V/cm), the concentration of working solution (EDTA), and pH buffer (0.01 M Na2CO3) were controlled. The CEEK with EDTA can maintain at relatively neutral pH to beneficially remove heavy metals due to appropriate EO flow, electromigration, and EDTA complexation. EDTA served as the chelating agent to react with lead in soils and its concentration plays the key factor for desorbing heavy metals from soils; the 0.1 M EDTA can achieve 79% of Pb depletion (from 3703 mg/kg to 781 mg/kg). The stoichiometric calculation can be roughly used to estimate the Pb removal efficiency based on the 1:1 M ratio of Pb to EDTA and ignores other reactions between EDTA and soil constituents. The CEEK technique with 0.1 M EDTA can remove 63% Pb (from 3430 mg/kg to 1260 mg/kg) within 6-day treatment.
More Related Videos
10:23Characterizing Mediated Extracellular Electron Transfer in Lactic Acid Bacteria with a Three-Electrode, Two-Chamber Bioelectrochemical System
Published on: August 23, 2024
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023
Related Concept Videos
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Auxiliary Complexing Reagents
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
EDTA: Indirect and Alkalimetric Titration