Related Experiment Video
Updated: Jan 19, 2026

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Spatio-temporal variations of indoor air quality in a university library
Veerendra Sahu1, Bhola Ram Gurjar1
1Department of Civil Engineering, Indian Institute of Technology, Roorkee, India.
Abstract:
The present study aims to assess the air quality status in the central library of Indian Institute of Technology Roorkee, India. Pollutants concentrations (i.e. PM10, PM2.5, PM1 and TVOC) and comfort parameters i.e. CO2, temperature and relative humidity were monitored across all floors of the library. Air quality was found to vary significantly (P < 0.05) among the different floors of the library. The average concentration of PM10, PM2.5 and PM1 was found to be highest at the first floor. On the other hand, the highest concentration of TVOC (51.7 ± 30 ppb) and CO2 (838.4 ± 99 ppm) was observed at the ground floor. Pollutant concentration was higher in the morning hours. The indoor pollutants were found positively correlated with each other except relative humidity. Indoor to outdoor ratio for PM1, TVOC and CO2 was found to be greater than 1, which indicate a substantial contribution from indoor sources. Exceedance of WHO guidelines was observed for the daily average PM2.5 concentration.Abbreviation: IAQ: indoor air quality; ASHRAE: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; WHO: World Health Organization; PM: particulate matter; VOC: volatile organic carbon; CO2: carbon dioxide; TVOC: Total volatile organic compound; RH: relative humidity; HVAC: heating ventilation and air-conditioning; PID: Photo Ionization Detector; PTFE: Polytetrafluoroethylene; NDIR: Non-dispersive infra-red.
More Related Videos
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical...
Application of Integration: Problem Solving

