Effect of self-initiated and fully-automated self-measurement on blood pressure
Rosanne T Berkhof1, Katia Gazzola1,2, Bert-Jan H van den Born3
1Department of Vascular Medicine, Amsterdam UMC location Academic Medical Center, Amsterdam, The Netherlands.
Abstract:
Self-measurement of blood pressure (BP) is regularly used to diagnose hypertension and to monitor BP at home. We recently showed that self-measurement of BP may elicit a pressor or 'auto-cuff' response. In this study we examined whether the pressor response is different between self-initiated and fully-automated BP measurement. We performed two randomized crossover studies in outpatients visiting a hypertension clinic. The first cohort of 52 participants performed six unattended self-initiated and six fully-automated BP measurements, while continuously monitoring BP and central haemodynamics using finger photoplethysmography. The second cohort consisted of 120 patients who performed three self-initiated and three fully-automated BP measurements. In the first cohort (mean age 61.2 ± 10.4 years, mean office BP 142.0 ± 19.9/82.5 ± 12.2 mmHg, 36.7% female) average systolic and diastolic BP increased by 7.3 ± 8.5/3.3 ± 4.0 mmHg in the group with self-initiated BP measurements, while BP increased by 3.3 ± 6.3/1.4 ± 3.0 mmHg during fully-automated measurements (p = 0.002/p = 0.002 for difference between groups). The higher BP increase during self-initiated BP measurements resulted from an increase in heart rate and cardiac output. In the second cohort (mean age 58.0 ± 14.1 years, mean office BP 153.6 ± 23.8/86.3 ± 14.0 mmHg, 44.1% female) self-initiated BP measurement resulted in a 2.1 ± 6.8/0.9 ± 4.0 mmHg higher systolic and diastolic BP compared with fully-automated self-measurement (p = 0.001/0.018). In conclusion, our findings suggest that self-initiated BP measurement using a fully-automated method results in a more reliable BP compared with a self-initiated semi-automated method by attenuating the auto-cuff response. These findings may have implications for the self-measurement of BP.
Related Concept Videos
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.