Related Experiment Video
Updated: Jan 19, 2026

Analyses of Proteinuria, Renal Infiltration of Leukocytes, and Renal Deposition of Proteins in Lupus-prone MRL/lpr Mice
Published on: June 8, 2022
Impact of different preanalytical conditions on results of lupus anticoagulant tests
Ann Helen Kristoffersen1,2, Ida Jansrud Hammer3, Solveig Vannes1
1Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Helse Bergen, Bergen, Norway.
Introduction:
The currently recommended preanalytical conditions for lupus anticoagulant (LA) analysis require analyzing samples in fresh or freshly frozen platelet-poor plasma. The aim of this study was to evaluate whether alternative and less cumbersome preanalytical procedures for LA testing give significantly different results compared to recommended conditions.
Materials And Methods:
Citrated blood samples were drawn from 29 study participants, 15 with negative and 14 with positive LA results. The samples were processed according to the ISTH guideline for LA testing and compared to several alternative preanalytical conditions. Measurements were performed using the dilute Russell's viper venom time (DRVVT) and silica clotting time (SCT), both screen and confirm, on a STA-R Evolution analyzer. Stability criteria were based upon biological variation.
Results:
All DRVVT tests (normalized screen, confirm, and screen/confirm ratio) met the stability criteria for all the preanalytical conditions. The SCT tests (normalized screen, confirm, and screen/confirm ratio) met the stability criteria only when treated according to the ISTH guideline, except for SCT normalized screen/confirm ratio which also met the stability criteria for double-centrifuged aliquoted plasma stored in room temperature for 24 hours and then analyzed "fresh" or after being frozen. One warfarin-treated patient was reclassified from positive to negative for DRVVT after the preanalytical modifications, while 2 of 29 participants became falsely positive for 2 of 8 conditions for SCT.
Conclusions:
The DRVVT assays met the criteria for stability for all preanalytical conditions tested, while the SCT assays should be interpreted with caution if the preanalytical guidelines from ISTH are not followed.